Počet záznamů: 1  

Comparative study of total power density at a substrate in pulsed DC magnetron and hollow-cathode plasma jet sputtering systems

  1. 1.
    SYSNO ASEP0335019
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevComparative study of total power density at a substrate in pulsed DC magnetron and hollow-cathode plasma jet sputtering systems
    Překlad názvuPorovnávací studie celkové výkonové hustoty na substrát v pulzním DC magnetronovém výboji a v plazma-jetu s dutou katodou
    Tvůrce(i) Čada, Martin (FZU-D) RID, ORCID, SAI
    Virostko, Petr (FZU-D)
    Kment, Štěpán (FZU-D) RID, ORCID
    Hubička, Zdeněk (FZU-D) RID, ORCID, SAI
    Zdroj.dok.Plasma Processes and Polymers. - : Wiley - ISSN 1612-8850
    Roč. 6, S1 (2009), S247-S252
    Poč.str.6 s.
    AkceInternational Conference on Plasma Surface Engineering /11./
    Datum konání15.09.2008-19.09.2008
    Místo konáníGarmisch Partenkirchen
    ZeměDE - Německo
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.DE - Německo
    Klíč. slovacalorimeter probe ; floating substrate ; magnetron ; plasma jet ; pulsed discharge
    Vědní obor RIVBH - Optika, masery a lasery
    CEPKAN301370701 GA AV ČR - Akademie věd
    KJB100100707 GA AV ČR - Akademie věd
    KJB100100805 GA AV ČR - Akademie věd
    1M06002 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    CEZAV0Z10100522 - FZU-D (2005-2011)
    UT WOS000272302900050
    DOI10.1002/ppap.200930611
    AnotaceThe pulsed DC magnetron and hollow-cathode plasma jet sources have been studied from the point of view of total energy flux density at a ‘‘floating’’ substrate. Both plasma sources were operated under identical experimental conditions and differences between both systems were investigated. The aim of this work is focused on the characterization of total power density at electrically isolated substrate for various duty cycles and for different pulsing frequencies. A calorimeter probe with incorporated thermocouple junction was used for measurement of the total power density on the substrate. The main results from the calorimeter probe show clearly that total power density at the substrate is much higher for the planar magnetron operating at low duty cycle and high pulsing frequency than for the plasma jet. The total power density measured in the planar magnetron depends more strongly on the duty cycle and the pulsing frequency than measured in the plasma jet.
    PracovištěFyzikální ústav
    KontaktKristina Potocká, potocka@fzu.cz, Tel.: 220 318 579
    Rok sběru2010