Time-resolved optical diagnostics of ns-pulsed underwater discharge
- 1.0469554 - ÚFP 2017 RIV SK eng A - Abstrakt
Pongrác, Branislav - Šimek, Milan - Babický, Václav - Člupek, Martin - Lukeš, Petr
Time-resolved optical diagnostics of ns-pulsed underwater discharge.
Book of Abstracts ICPM 6. Bratislava: Elsevier B.V., 2016 - (Hensel, K.; Tarabová, B.; Kučerová, T.; Kovalová, Z.; Janda, M.; Machala, Z.). s. 170. ISBN 978-80-8147-066-0.
[International Conference on Plasma Medicine (ICPM-6)/6./. 04.09.2016-09.09.2016, Bratislava]
Grant CEP: GA ČR(CZ) GA15-12987S
Institucionální podpora: RVO:61389021
Klíčová slova: optical diagnostics * pulsed electrical discharges * emission spectra
Kód oboru RIV: BL - Fyzika plazmatu a výboje v plynech
Pulsed electrical discharges in liquids have been generated by ns pulses. These kind of discharges are generated most probably without the presence of initial bubbles. In the region between 320 and 750 nm, we observed broadband emission spectra profile occurring only during the first ~20 ns. The origin of these emission spectra is not clear yet and its identification is still in progress. After the initial 20 ns, when this almost continuum spectra profile gradually disappeared, some peaks observed typically also for μs-pulsed water discharges with bubbles (e.g. Hα, OI) were detected.
Trvalý link: http://hdl.handle.net/11104/0267349