Počet záznamů: 1
Ultrasonic detection of ductile-to-brittle transitions in free-cutting aluminum alloys
- 1.0434238 - ÚT 2016 RIV GB eng J - Článek v odborném periodiku
Nejezchlebová, J. - Seiner, Hanuš - Ševčík, Martin - Landa, Michal - Karlík, M.
Ultrasonic detection of ductile-to-brittle transitions in free-cutting aluminum alloys.
NDT & E International. Roč. 69, January 2015 (2015), s. 40-47. ISSN 0963-8695. E-ISSN 1879-1174
Grant CEP: GA ČR GB14-36566G
Institucionální podpora: RVO:61388998
Klíčová slova: aluminum alloys * laser ultrasound * ductile-to-brittle * elastic constants * resonant ultrasound spectroscopy
Kód oboru RIV: BI - Akustika a kmity
Impakt faktor: 1.871, rok: 2015 ; AIS: 0.695, rok: 2015
Web výsledku:
http://www.sciencedirect.com/science/article/pii/S0963869514001200DOI: https://doi.org/10.1016/j.ndteint.2014.09.007
Resonant ultrasound spectroscopy (RUS) is applied to detect the ductile-to-brittle and brittle-to-ductile transitions in an AA6262 free-cutting aluminum alloy during thermal cycling. The proposed RUS approach is compared with differential scanning calorimetry (DSC); the latter method is shown to be unable to detect the transition temperatures especially when transition intervals are broad.
Trvalý link: http://hdl.handle.net/11104/0238748
Počet záznamů: 1