Počet záznamů: 1  

Measurement of surface properties of pyrolytic graphite for biomedical applications

  1. 1.
    0142232 - FGU-C 20010291 RIV PL eng J - Článek v odborném periodiku
    Starý, V. - Bačáková, Lucie - Glogar, Petr - Horník, J. - Jirka, Ivan - Švorčík, V.
    Measurement of surface properties of pyrolytic graphite for biomedical applications.
    Engineering of Biomaterials. Roč. 4, 17-19 (2001), s. 10-11. ISSN 1429-7248.
    [Konferencja Naukowa "Biomaterialy w medycynie i weterynarii" /11./. Rytro, 14.10.2001-17.10.2001]
    Grant CEP: GA ČR GA106/99/0626
    Výzkumný záměr: CEZ:AV0Z5011922
    Klíčová slova: carbon fibre-reinforced carbon composites * osteoblast
    Kód oboru RIV: EI - Biotechnologie a bionika

    On carbon fibre-reinforced carbon composites, surfaces either with various roughness or with various chemical state were prepared by grinding with metalographic paper 4000, polishing with diamond paste (3/2,1/2 grade) or by coating with pyrolytic graphite, resp. On these surfaces, wetting angle, free polar energy, presence of carbonyl and carboxyl groups and other physicochemical parameters were correlated with adhesion and subsequent growth of osteoblast-like MG-63 cells.