Výsledky vyhledávání
- 1.0559367 - ÚTAM 2023 RIV GB eng J - Článek v odborném periodiku
Hasn, S. - Pichotka, M. - Dušek, K. - Vavřík, Daniel
Investigation of BGA underfill process based on multipositional computed tomography.
Journal of Instrumentation. Roč. 17, č. 6 (2022), č. článku P06037. ISSN 1748-0221. E-ISSN 1748-0221
Grant CEP: GA MŠMT(CZ) EF16_019/0000766
Institucionální podpora: RVO:68378297
Klíčová slova: detection of defects * image processing * inspection with X-rays
Obor OECD: Applied mechanics
Impakt faktor: 1.3, rok: 2022
Způsob publikování: Omezený přístup
https://doi.org/10.1088/1748-0221/17/06/P06037
Trvalý link: https://hdl.handle.net/11104/0332704 - 2.0522840 - ÚTAM 2021 RIV GB eng J - Článek v odborném periodiku
Hasn, S. - Vavřík, Daniel - Dušek, K. - Pichotka, M.
μ-CT investigation of tin whisker growth mechanisms.
Journal of Instrumentation. Roč. 15, č. 2 (2020), č. článku C02043. ISSN 1748-0221. E-ISSN 1748-0221
Grant CEP: GA MŠMT(CZ) EF16_019/0000766
Institucionální podpora: RVO:68378297
Klíčová slova: inspection with x-rays * detection of defects * computerized tomography (CT) and computed radiography (CR) * X-ray detectors
Obor OECD: Materials engineering
Impakt faktor: 1.415, rok: 2020
Způsob publikování: Omezený přístup
https://doi.org/10.1088/1748-0221/15/02/C02043
Trvalý link: http://hdl.handle.net/11104/0307264 - 3.0497929 - ÚTAM 2019 RIV GB eng J - Článek v odborném periodiku
Vavřík, Daniel - Kytýř, Daniel - Mühleder, S. - Vopálenský, Michal - Beneš, Pavel - Pichotka, M. - Kumpová, Ivana - Koudelka_ml., Petr
High resolution X-ray micro-CT imaging of fibrin scaffold using large area single photon counting detector.
Journal of Instrumentation. Roč. 13, č. 12 (2018), č. článku C12006. ISSN 1748-0221. E-ISSN 1748-0221.
[International Workshop on Radiation Imaging Detectors /20./. Sundsvall, 24.06.2018-28.06.2018]
Grant CEP: GA MŠMT(CZ) EF16_019/0000766
GRANT EU: European Commission(XE) ATCZ133 - Kompetenzzentrum MechanoBiologie
Klíčová slova: computerized tomography (CT) * computed radiography (CR) * pixelated detectors * VLSI electronics * inspection with x-rays
Obor OECD: Applied mechanics
Impakt faktor: 1.366, rok: 2018
https://doi.org/10.1088/1748-0221/13/12/C12006
Trvalý link: http://hdl.handle.net/11104/0290391Název souboru Staženo Velikost Komentář Verze Přístup 0497929_2018_Vavrik_et_al_High_resolution_X-ray_micro-CT_imaging_of_fibrin_scaffold_using_large_area_single_photon_counting_detector.pdf 0 20.8 MB Autorský postprint povolen - 4.0474192 - ÚTAM 2018 RIV GB eng J - Článek v odborném periodiku
Vavřík, Daniel - Jakůbek, Jan - Kumpová, Ivana - Pichotka, M.
Laboratory based study of dynamical processes by 4D X-ray CT with sub-second temporal resolution.
Journal of Instrumentation. Roč. 12, February (2017), č. článku C02010. ISSN 1748-0221. E-ISSN 1748-0221.
[International Workshop on Radiation Imaging Detectors /18./. Barcelona, 03.07.2016-07.07.2016]
Grant CEP: GA ČR(CZ) GA15-07210S; GA MŠMT(CZ) LO1219
Klíčová slova: computerized tomography (CT) * computed radiography (CR) * inspection with x-rays * pixelated detectors and associated VLSI electronics * X-ray radiography and digital radiography (DR)
Obor OECD: Electrical and electronic engineering
Impakt faktor: 1.258, rok: 2017
http://iopscience.iop.org/article/10.1088/1748-0221/12/02/C02010
Trvalý link: http://hdl.handle.net/11104/0271301 - 5.0460560 - ÚTAM 2017 RIV NL eng J - Článek v odborném periodiku
Vavřík, Daniel - Jakůbek, J. - Kumpová, Ivana - Pichotka, M.
Dual energy CT inspection of a carbon fibre reinforced plastic composite combined with metal components.
Case Studies in Nondestructive Testing and Evaluation. 6, Part B, November (2016), s. 47-55. ISSN 2214-6571
Grant CEP: GA MŠMT(CZ) LO1219; GA ČR(CZ) GA15-07210S
Klíčová slova: dual energy computed tomography * carbon fibre reinforced plastic composite * metal artefact suppression
Kód oboru RIV: JI - Kompozitní materiály
http://www.sciencedirect.com/science/article/pii/S2214657116300107
Trvalý link: http://hdl.handle.net/11104/0260604 - 6.0458310 - ÚTAM 2017 RIV GB eng J - Článek v odborném periodiku
Vavřík, Daniel - Jandejsek, Ivan - Pichotka, M.
Correction of the X-ray tube spot movement as a tool for improvement of the micro-tomography quality.
Journal of Instrumentation. Roč. 11, č. 1 (2016), C01029. ISSN 1748-0221. E-ISSN 1748-0221
Grant CEP: GA MŠMT(CZ) LO1219
Klíčová slova: computerized tomography (CT) * computed radiography (CR) * inspection with x-rays * detector alignment and calibration methods
Kód oboru RIV: AL - Umění, architektura, kulturní dědictví
Impakt faktor: 1.220, rok: 2016
http://iopscience.iop.org/article/10.1088/1748-0221/11/01/C01029
Trvalý link: http://hdl.handle.net/11104/0258591