Počet záznamů: 1  

On-the-fly fast X-ray tomography using a CdTe pixelated detector – application in mechanical testing

  1. 1.
    SYSNO ASEP0494940
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevOn-the-fly fast X-ray tomography using a CdTe pixelated detector – application in mechanical testing
    Tvůrce(i) Kumpová, Ivana (UTAM-F) RID, SAI, ORCID
    Vopálenský, Michal (UTAM-F) RID, ORCID, SAI
    Fíla, Tomáš (UTAM-F) RID, SAI, ORCID
    Kytýř, Daniel (UTAM-F) SAI, RID, ORCID
    Vavřík, Daniel (UTAM-F) RID, SAI, ORCID
    Pichotka, Martin (UTAM-F)
    Jakůbek, Jan (UTAM-F)
    Keršner, Z. (CZ)
    Klon, J. (CZ)
    Seitl, S. (CZ)
    Sobek, J. (CZ)
    Celkový počet autorů11
    Zdroj.dok.IEEE Transactions on Nuclear Science. - : Institute of Electrical and Electronics Engineers - ISSN 0018-9499
    Roč. 65, č. 12 (2018), s. 2870-2876
    Poč.str.14 s.
    Forma vydáníTištěná - P
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovacadmium telluride (CdTe) detectors ; fracture mechanics ; material characterization ; mechanical testing
    Vědní obor RIVJB - Senzory, čidla, měření a regulace
    Obor OECDElectrical and electronic engineering
    CEPEF16_019/0000766 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaUTAM-F - RVO:68378297
    UT WOS000454236100004
    EID SCOPUS85054508531
    DOI10.1109/TNS.2018.2873830
    AnotaceFast tomography measurements are still done almost exclusively within the domain of synchrotrons. However, recent progress in radio diagnostic instrumentation has enabled researchers to perform time-lapse computed tomography (4D-CT) even under laboratory conditions with standard X-Ray sources. Thus, fast time-dependent processes within materials with relatively high X-Ray attenuation can be monitored. The article describes the in-situ tomographic monitoring of crack formation and propagation in a quasi-brittle silicate matrix composite subjected to three point bending. A three-dimensional CT volume containing the region of interest (ROI) in the specimen is imaged over a period of time while the continuously increasing load causes crack initiation and propagation, creating a dynamic volume dataset. An acquisition time of 50 seconds for one full angle tomography with 400 projections makes this tomographic system one of the fastest systems in the world. The resulting visualizations provide qualitative information concerning progressive crack propagation within areas of lower material density. Differential images then allow displaying the spatial orientation of the crack over time. The results were further processed for a quantitative analysis of image quality using various methods of beam hardening correction.
    PracovištěÚstav teoretické a aplikované mechaniky
    KontaktKulawiecová Kateřina, kulawiecova@itam.cas.cz, Tel.: 225 443 285
    Rok sběru2019
    Elektronická adresahttps://ieeexplore.ieee.org/document/8482343