Počet záznamů: 1  

The Repetitive Detection of Toluene with Bioluminescence Bioreporter Pseudomonas putida TVA8 Encapsulated in Silica Hydrogel on an Optical Fiber.

  1. 1.
    SYSNO ASEP0460411
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevThe Repetitive Detection of Toluene with Bioluminescence Bioreporter Pseudomonas putida TVA8 Encapsulated in Silica Hydrogel on an Optical Fiber.
    Tvůrce(i) Kuncová, Gabriela (UCHP-M) RID, SAI
    Ishizaki, Takayuki (UCHP-M)
    Solovyev, Andrey (UCHP-M) RID, ORCID, SAI
    Trögl, J. (CZ)
    Ripp, S. (US)
    Zdroj.dok.Materials. - : MDPI
    Roč. 9, č. 6 (2016), s. 467
    Poč.str.10 s.
    Jazyk dok.eng - angličtina
    Země vyd.CH - Švýcarsko
    Klíč. slovabioluminescent biosensor ; silica gel ; encapsulation
    Vědní obor RIVCC - Organická chemie
    Institucionální podporaUCHP-M - RVO:67985858
    UT WOS000378630600066
    EID SCOPUS84975693032
    DOI10.3390/ma9060467
    AnotaceLiving cells of the lux-based bioluminescent bioreporter Pseudomonas putida TVA8 were encapsulated in a silica hydrogel attached to the distal wider end of a tapered quartz fiber. Bioluminescence of immobilized cells was induced with toluene at high (26.5 mg/L) and low (5.3 mg/L) concentrations. Initial bioluminescence maxima were achieved after >12 h. One week after immobilization, a biofilm-like layer of cells had formed on the surface of the silica gel. This resulted in shorter response times and more intensive bioluminescence maxima that appeared as rapidly as 2 h after toluene induction. Considerable second bioluminescence maxima were observed after inductions with 26.5 mg toluene/L. The second and third week after immobilization the biosensor repetitively and semiquantitatively detected toluene in buffered medium. Due to silica gel dissolution and biofilm detachment, the bioluminescent signal was decreasing 20–32 days after immobilization and completely extinguished after 32 days. The reproducible formation of a surface cell layer on the wider end of the tapered optical fiber can be translated to various whole cell bioluminescent
    biosensor devices and may serve as a platform for in-situ sensors.
    PracovištěÚstav chemických procesů