Počet záznamů: 1  

Solid phase extraction methods for purification of positively charged oligosaccharides and glycans

  1. 1.
    SYSNO ASEP0577618
    Druh ASEPA - Abstrakt
    Zařazení RIVZáznam nebyl označen do RIV
    Zařazení RIVNení vybrán druh dokumentu
    NázevSolid phase extraction methods for purification of positively charged oligosaccharides and glycans
    Tvůrce(i) Smolková, Denisa (UIACH-O)
    Moravcová, Dana (UIACH-O) RID, ORCID
    Lavická, Jana (UIACH-O) ORCID, RID
    Celkový počet autorů3
    Zdroj.dok.CECE 2023. 18th International Interdisciplinary Meeting on Bioanalysis. - Brno : Ústav analytické chemie AV ČR, v. v. i., 2023 - ISBN 978-80-908154-0-7
    S. 32-32
    Poč.str.1 s.
    Forma vydáníOnline - E
    AkceCECE 2023. International Interdisciplinary Meeting on Bioanalysis /18./
    Datum konání23.10.2023 - 25.10.2023
    Místo konáníBrno
    ZeměCZ - Česká republika
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.CZ - Česká republika
    Klíč. slovasolid phase extraction ; oligosaccharides ; glycans
    Vědní obor RIVCB - Analytická chemie, separace
    Obor OECDAnalytical chemistry
    CEPGA22-00236S GA ČR - Grantová agentura ČR
    Institucionální podporaUIACH-O - RVO:68081715
    AnotaceThe crucial step for the analysis of oligosaccharides and glycans by capillary electrophoresis (CE) and/or mass spectrometry (CE-MS) is their derivatization by label. The signal of the unreacted label is routinely significantly higher, indicating the need to deplete the unreacted label prior to analysis by CE. The suitability of five different solid-phase extraction sorbents (Spe-ed Amide-2, Chromabond HILIC, HyperSep Diol, Bond Elut PBA, and HyperSep Hypercarb) was tested for the clean-up and concentration of positively labeled maltooligosaccharides from the reaction mixture. Maltooligosaccharides containing four to seven glucose units were labeled by cationic tags (2-aminoethyl)trimethylammonium chloride and (carboxymethyl)trimethylammonium chloride hydrazide (Girard’s reagent T). Purified samples were analyzed by CE with conductivity detection to compare the purification selectivity and efficiency using the tested SPE materials. The amide-based sorbent gave the best results and was used to process the N-linked glycans enzymatically released from the ribonuclease B sample.
    PracovištěÚstav analytické chemie
    KontaktIveta Drobníková, drobnikova@iach.cz, Tel.: 532 290 234
    Rok sběru2024
    Elektronická adresahttps://www.ce-ce.org/user_uploads/CECE_2023/CECE%202023%20Proceedings.pdf
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.