Počet záznamů: 1  

Establishing the Quality Assurance programme for the strip sensor production of the ATLAS tracker upgrade including irradiation with neutrons, photons and protons to HL-LHC fluences

  1. 1.
    SYSNO ASEP0575430
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevEstablishing the Quality Assurance programme for the strip sensor production of the ATLAS tracker upgrade including irradiation with neutrons, photons and protons to HL-LHC fluences
    Tvůrce(i) Kopsalis, I. (GB)
    Allport, P. (GB)
    Bach, E. (ES)
    Federičová, Pavla (FZU-D) ORCID
    Kroll, Jiří (FZU-D) ORCID
    Kvasnička, Jiří (FZU-D) RID, ORCID
    Latoňová, Věra (FZU-D) ORCID
    Mikeštíková, Marcela (FZU-D) RID, ORCID
    Celkový počet autorů35
    Číslo článkuC05009
    Zdroj.dok.Journal of Instrumentation. - : Institute of Physics Publishing - ISSN 1748-0221
    Roč. 18, č. 5 (2023)
    Poč.str.13 s.
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovalarge detector systems for particle and astroparticle physics ; particle tracking detectors ; particle tracking detectors (Solid-state detectors)
    Vědní obor RIVBF - Elementární částice a fyzika vys. energií
    Obor OECDParticles and field physics
    CEPLTT17018 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    LM2018104 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Způsob publikováníOpen access
    Institucionální podporaFZU-D - RVO:68378271
    UT WOS001027108300003
    EID SCOPUS85159711516
    DOI10.1088/1748-0221/18/05/C05009
    AnotaceThe successful pre-production delivery of strip sensors for the new Inner Tracker (ITk) for the upgraded ATLAS detector at the High Luminosity LHC (HL-LHC) at CERN was completed and based on their performance full production has commenced. The overall delivery period is anticipated to last 4 years to complete the approximately 22000 sensors required for the ITk. For Quality Assurance (QA), a number of test structures designed by the collaboration, along with a large area diode and miniature version of the main sensor, are produced in every wafer by the foundry Hamamatsu Photonics K.K (HPK). As well as Quality Control (QC) checks on every main sensor,, samples of the QA pieces from each delivery batch are tested both before and after irradiation with results after exposure to neutrons, gammas or protons to fluences and doses corresponding to those anticipated after operation at the HL-LHC to roughly 1.5 times the ultimate integrated luminosity of 4000 fb-1.
    PracovištěFyzikální ústav
    KontaktKristina Potocká, potocka@fzu.cz, Tel.: 220 318 579
    Rok sběru2024
    Elektronická adresahttps://hdl.handle.net/11104/0349072
Počet záznamů: 1  