Počet záznamů: 1
How to Use Ion-Molecule Reaction Data Previously Obtained in Helium at 300 K in the New Generation of Selected Ion Flow Tube Mass Spectrometry Instruments Operating in Nitrogen at 393 K
- 1.
SYSNO ASEP 0574260 Druh ASEP J - Článek v odborném periodiku Zařazení RIV J - Článek v odborném periodiku Poddruh J Článek ve WOS Název How to Use Ion-Molecule Reaction Data Previously Obtained in Helium at 300 K in the New Generation of Selected Ion Flow Tube Mass Spectrometry Instruments Operating in Nitrogen at 393 K Tvůrce(i) Swift, Stefan James (UFCH-W)
Španěl, Patrik (UFCH-W) RID, ORCID
Sixtová, Nikola (UFCH-W)
Demarais, N. (NZ)Zdroj.dok. Analytical Chemistry. - : American Chemical Society - ISSN 0003-2700
Roč. 95, č. 29 (2023), s. 11157-11163Poč.str. 7 s. Jazyk dok. eng - angličtina Země vyd. US - Spojené státy americké Klíč. slova chemical reactions ; ions ; Volatile organic compounds Vědní obor RIV CF - Fyzikální chemie a teoretická chemie Obor OECD Physical chemistry CEP GA21-25486S GA ČR - Grantová agentura ČR Způsob publikování Open access Institucionální podpora UFCH-W - RVO:61388955 UT WOS 001030474400001 EID SCOPUS 85166425893 DOI 10.1021/acs.analchem.3c02173 Anotace Selected ion flow tube mass spectrometry (SIFT-MS) instruments have significantly developed since this technique was introduced more than 20 years ago. Most studies of the ion-molecule reaction kinetics that are essential for accurate analyses of trace gases and vapors in air and breath were conducted in He carrier gas at 300 K, while the new SIFT-MS instruments (optimized to quantify concentrations down to parts per trillion by volume) operate with N2 carrier gas at 393 K. Thus, we pose the question of how to reuse the data from the extensive body of previous literature using He at room temperature in the new instruments operating with N2 carrier gas at elevated temperatures. Experimentally, we found the product ions to be qualitatively similar, although there were differences in the branching ratios, and some reaction rate coefficients were lower in the heated N2 carrier gas. The differences in the reaction kinetics may be attributed to temperature, an electric field in the current flow tubes, and the change from He to N2 carrier gas. These results highlight the importance of adopting an updated reaction kinetics library that accounts for the new instruments’ specific conditions. In conclusion, almost all previous rate coefficients may be used after adjustment for higher temperatures, while some product ion branching ratios need to be updated. Pracoviště Ústav fyzikální chemie J.Heyrovského Kontakt Michaela Knapová, michaela.knapova@jh-inst.cas.cz, Tel.: 266 053 196 Rok sběru 2024 Elektronická adresa https://hdl.handle.net/11104/0344602
Počet záznamů: 1