Počet záznamů: 1  

Embedded-probes diagnostics for the COMPASS upgrade tokamak: a concept

  1. 1.
    SYSNO ASEP0570021
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevEmbedded-probes diagnostics for the COMPASS upgrade tokamak: a concept
    Tvůrce(i) Dimitrova, Miglena (UFP-V) ORCID
    Gerardin, Jonathan (UFP-V) ORCID
    Podolník, Aleš (UFP-V) ORCID
    Balner, Vojtěch (UFP-V)
    Mitov, M. (BG)
    Adámek, Jiří (UFP-V) RID, ORCID
    Ďuran, Ivan (UFP-V) RID, ORCID
    Weinzettl, Vladimír (UFP-V) RID, ORCID
    Veselovský, Viktor (UFP-V)
    Dejarnac, Renaud (UFP-V) RID, ORCID
    Komm, Michael (UFP-V) RID, ORCID
    Hron, Martin (UFP-V) RID, ORCID
    Pánek, Radomír (UFP-V) RID
    Celkový počet autorů13
    Číslo článkuP11018
    Zdroj.dok.Journal of Instrumentation. - : Institute of Physics Publishing - ISSN 1748-0221
    Roč. 17, č. 11 (2022)
    Poč.str.15 s.
    Jazyk dok.eng - angličtina
    Země vyd.GB - Velká Británie
    Klíč. slovaModels and simulations ; Plasma diagnostics probes
    Vědní obor RIVBL - Fyzika plazmatu a výboje v plynech
    Obor OECDFluids and plasma physics (including surface physics)
    CEPEF16_019/0000768 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    LM2018117 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    8D15001 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Způsob publikováníOmezený přístup
    Institucionální podporaUFP-V - RVO:61389021
    UT WOS000924954800008
    EID SCOPUS85142420977
    DOI10.1088/1748-0221/17/11/P11018
    AnotaceThis article introduces a concept based on flush-mounted probes embedded in the limiters of the COMPASS-Upgrade tokamak. Main issues related to flush probe geometry are taken into account and discussed. Calculations of heat fluxes and the incident angle of the field lines on the different limiters using the PFCflux code are performed to support in probe arrangement optimization. Model current-voltage characteristics for a flush probe are simulated using the SPICE2 code and their dependence on the angle of incidence is studied. The results are used to predict the current to be collected by the flush probes for different magnetic fields and to examine the reliability of the proposed diagnostics. A discussion is included on the capability of the electronic system considered for the measurements.
    PracovištěÚstav fyziky plazmatu
    KontaktVladimíra Kebza, kebza@ipp.cas.cz, Tel.: 266 052 975
    Rok sběru2023
    Elektronická adresahttps://iopscience.iop.org/article/10.1088/1748-0221/17/11/P11018
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.