Počet záznamů: 1  

Characterisation of the auxiliary heating power delivered by the 40 keV neutral beam injectors on the COMPASS tokamak

  1. 1.
    SYSNO ASEP0566724
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevCharacterisation of the auxiliary heating power delivered by the 40 keV neutral beam injectors on the COMPASS tokamak
    Tvůrce(i) Bogár, Klára (UFP-V) ORCID
    Varju, Jozef (UFP-V) ORCID
    Havlíček, Josef (UFP-V) RID, ORCID
    Stöckel, Jan (UFP-V) RID
    Podolník, Aleš (UFP-V) ORCID
    Hron, Martin (UFP-V) RID, ORCID
    Pánek, Radomír (UFP-V) RID
    Celkový počet autorů7
    Číslo článku025004
    Zdroj.dok.Plasma Physics and Controlled Fusion. - : Institute of Physics Publishing - ISSN 0741-3335
    Roč. 65, č. 2 (2023)
    Poč.str.14 s.
    Jazyk dok.eng - angličtina
    Země vyd.GB - Velká Británie
    Klíč. slovaneutral beam injection ; auxilliary heating ; COMPASS tokamak ; power balance ; beam duct scraping
    Vědní obor RIVBL - Fyzika plazmatu a výboje v plynech
    Obor OECDFluids and plasma physics (including surface physics)
    CEPLM2018117 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    EF16_019/0000768 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Způsob publikováníOmezený přístup
    Institucionální podporaUFP-V - RVO:61389021
    UT WOS000901498800001
    EID SCOPUS85145007729
    DOI10.1088/1361-6587/aca629
    AnotaceTwo identical neutral beam injectors (NBIs) have been installed on the COMPASS tokamak. Each of them is capable of producing a deuterium (or hydrogen, helium) neutral beam with nominal power of up to 400 kW at 40 keV. Since the COMPASS tokamak is a compact machine, the design of the neutral beams was carefully optimized to fit the neutral beam through the narrow ports of the tokamak. However, once the neutral beams are operated out of the scope of their optimal parameters, additional power losses occur due to neutral beam scraping. This article investigates the amount of power loss due to neutral beam scraping. The losses are calculated using the neutral beam models and measured neutral beam parameters. The calculated results are compared with the measured power delivered into the plasma. Two different neutral beam models are employed. One describes the neutral beam as a sum of small beamlets, which are Gaussian-like. The second one describes the neutral beam as a single Gaussian beam. The amount of the power lost to scraping is determined by both models and compared. Neutral beam parameters, the input parameters for both models, are derived from the Doppler-shifted spectra emitted by fast neutral atoms. It is shown that when operating NBIs at nominal parameters, the scraping losses are negligible ( <
    PracovištěÚstav fyziky plazmatu
    KontaktVladimíra Kebza, kebza@ipp.cas.cz, Tel.: 266 052 975
    Rok sběru2023
    Elektronická adresahttps://iopscience.iop.org/article/10.1088/1361-6587/aca629
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.