Počet záznamů: 1
Operation and performance of the ATLAS semiconductor tracker in LHC Run 2
- 1.
SYSNO ASEP 0565743 Druh ASEP J - Článek v odborném periodiku Zařazení RIV J - Článek v odborném periodiku Poddruh J Článek ve WOS Název Operation and performance of the ATLAS semiconductor tracker in LHC Run 2 Tvůrce(i) Aad, G. (FR)
Abbott, B. (US)
Abbott, D.C. (US)
Chudoba, Jiří (FZU-D) RID, ORCID
Hejbal, Jiří (FZU-D) RID, ORCID
Hladík, Ondřej (FZU-D) ORCID
Jačka, Petr (FZU-D) ORCID
Kepka, Oldřich (FZU-D) RID, ORCID
Kroll, Jiří (FZU-D) ORCID
Kupčo, Alexander (FZU-D) RID, ORCID
Latoňová, Věra (FZU-D) ORCID
Lokajíček, Miloš (FZU-D) RID, ORCID
Lysák, Roman (FZU-D) RID, ORCID
Marčišovský, Michal (FZU-D) RID, ORCID
Mikeštíková, Marcela (FZU-D) RID, ORCID
Němeček, Stanislav (FZU-D) RID, ORCID
Penc, Ondřej (FZU-D) ORCID
Šícho, Petr (FZU-D) RID, ORCID
Staroba, Pavel (FZU-D) RID, ORCID
Svatoš, Michal (FZU-D) RID, ORCID
Taševský, Marek (FZU-D) RID, ORCIDCelkový počet autorů 2902 Číslo článku P01013 Zdroj.dok. Journal of Instrumentation. - : Institute of Physics Publishing - ISSN 1748-0221
Roč. 17, č. 1 (2022)Poč.str. 55 s. Jazyk dok. eng - angličtina Země vyd. GB - Velká Británie Klíč. slova ATLAS ; performance ; tracking detector Vědní obor RIV BF - Elementární částice a fyzika vys. energií Obor OECD Particles and field physics CEP LM2018104 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy Výzkumná infrastruktura e-INFRA CZ - 90140 - CESNET, zájmové sdružení právnických osob Způsob publikování Open access Institucionální podpora FZU-D - RVO:68378271 UT WOS 000766149300002 EID SCOPUS 85124139113 DOI 10.1088/1748-0221/17/01/P01013 Anotace The semiconductor tracker (SCT) is one of the tracking systems for charged particles in the ATLAS detector. It consists of 4088 silicon strip sensor modules. During Run 2 (2015–2018) the Large Hadron Collider delivered an integrated luminosity of 156 fb−1−1 to the ATLAS experiment at a centre-of-mass proton-proton collision energy of 13 TeV. The instantaneous luminosity and pile-up conditions were far in excess of those assumed in the original design of the SCT detector. Due to improvements to the data acquisition system, the SCT operated stably throughout Run 2. It was available for 99.9% of the integrated luminosity and achieved a data-quality efficiency of 99.85%. Detailed studies have been made of the leakage current in SCT modules and the evolution of the full depletion voltage, which are used to study the impact of radiation damage to the modules. Pracoviště Fyzikální ústav Kontakt Kristina Potocká, potocka@fzu.cz, Tel.: 220 318 579 Rok sběru 2023 Elektronická adresa https://hdl.handle.net/11104/0337253
Počet záznamů: 1