Počet záznamů: 1  

Fusion DEMO sCO2 layout design with battery farm

  1. 1.
    SYSNO ASEP0565691
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevFusion DEMO sCO2 layout design with battery farm
    Tvůrce(i) Syblík, J. (CZ)
    Entler, Slavomír (UFP-V) ORCID
    Veselý, L. (CZ)
    Štěpánek, J. (CZ)
    Dostál, V. (CZ)
    Celkový počet autorů5
    Číslo článku123730
    Zdroj.dok.Energy. - : Elsevier - ISSN 0360-5442
    Roč. 249, June (2022)
    Poč.str.9 s.
    Jazyk dok.eng - angličtina
    Země vyd.GB - Velká Británie
    Klíč. slovaBattery ; Energy storage ; eu demo ; Fusion ; Optimization ; Supercritical CO 2
    Vědní obor RIVBL - Fyzika plazmatu a výboje v plynech
    Obor OECDFluids and plasma physics (including surface physics)
    Způsob publikováníOmezený přístup
    Institucionální podporaUFP-V - RVO:61389021
    UT WOS000794028600013
    EID SCOPUS85126522501
    DOI10.1016/j.energy.2022.123730
    AnotaceNuclear fusion is a promising low-carbon and low-emission source of energy. One of the first fusion power plants will be the European Union's demonstration fusion power plant DEMO. Among the key attributes that influence the whole DEMO design is the fusion reactor pulse operation. Due to the power fluctuations of the power source, there will be a significant impact on the power plant technology, turbine, etc. Therefore, a power conversion system based on a supercritical CO2 capable of operating in two nominal power levels is proposed. The system operates in nominal parameters during the entire power cycle without the need for thermal power pulses balancing. Unlike other designs, instead of connecting the energy storage system directly to the heat transfer system, this article proposes a layout with an energy storage system behind the generator. Power pulses are balanced using a battery farm, compensating the fluctuations in the gross power and power plant self-consumption. Power conversion system is based on a sCO2 Brayton simple cycle with regeneration and includes technology for nominal operation at two levels of thermal power. Optimization of the proposed layout shows thermodynamic net efficiency of 24 %.
    PracovištěÚstav fyziky plazmatu
    KontaktVladimíra Kebza, kebza@ipp.cas.cz, Tel.: 266 052 975
    Rok sběru2023
    Elektronická adresahttps://www.sciencedirect.com/science/article/pii/S0360544222006338?via%3Dihub