Počet záznamů: 1
Finding Geometry of Two Micrometers Using Affine Transformation
- 1.
SYSNO ASEP 0565255 Druh ASEP C - Konferenční příspěvek (mezinárodní konf.) Zařazení RIV D - Článek ve sborníku Název Finding Geometry of Two Micrometers Using Affine Transformation Tvůrce(i) Czebe, J. (CZ)
Horák, David (UGN-S) SAI, ORCID
Tůma, J. (CZ)Celkový počet autorů 3 Číslo článku 9454622 Zdroj.dok. Proceedings of the 22nd International Carpathian Control Conference (ICCC). - New York : Institute of Electrical and Electronics Engineers Inc., 2021 - ISBN 978-172818609-2 Poč.str. 7 s. Forma vydání Online - E Akce ICCC 2021 : International Carpathian Control Conference /22./ Datum konání 31.05.2021 - 01.06.2021 Místo konání Velke Karlovice Země CZ - Česká republika Typ akce WRD Jazyk dok. eng - angličtina Země vyd. US - Spojené státy americké Klíč. slova calibration ; data processing ; environment friendly ; micrometer ; transformation Vědní obor RIV JD - Využití počítačů, robotika a její aplikace Obor OECD Automation and control systems CEP GA19-11441S GA ČR - Grantová agentura ČR Způsob publikování Omezený přístup Institucionální podpora UGN-S - RVO:68145535 EID SCOPUS 85113372380 DOI 10.1109/ICCC51557.2021.9454622 Anotace A significant part of Industry 4.0 is collecting data during manufacturing and optimizing production, and prolonging the machine lifetime. In our case, we propose to minimize the depth of cut on CNC to prolong cylinder lifetime in a rolling mill. Currently used measuring methods (precise template, clamp micrometer) without feedback are replaced with two 2-D micrometers. In our solution, we directly clamped the measuring head containing two micrometers on CNC's linear guidance. We propose a thin slice of metal (calibration template) with specific geometry designed for ongoing calibration in each cylinder's measuring cycle. The article's primary goal is to introduce a novel method of precisely processing data from both micrometers and one relative position (axis X, Z) given by CNCs linear guidance. Our team verified the Calibration Template's (CT) real profile on a Coordinate Measuring Machine (CMM).All horizontal sections of the CT are selected from measured data and fitted to the CT's corresponding section. All sections are replaced with landmarks to find the optimal transformation between both micrometer's spaces in the next step. Then we apply the found micrometer's geometry on raw data to compare the resulting CT's profile against the profile from CMM. Pracoviště Ústav geoniky Kontakt Lucie Gurková, lucie.gurkova@ugn.cas.cz, Tel.: 596 979 354 Rok sběru 2023 Elektronická adresa https://ieeexplore.ieee.org/document/9454622
Počet záznamů: 1