Počet záznamů: 1  

Thermal-stress-induced birefringence management of complex laser systems by means of polarimetry

  1. 1.
    SYSNO ASEP0564270
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevThermal-stress-induced birefringence management of complex laser systems by means of polarimetry
    Tvůrce(i) Slezák, Ondřej (FZU-D) RID, ORCID
    Sawicka-Chyla, Magdalena (FZU-D)
    Divoký, Martin (FZU-D) RID, ORCID
    Pilař, Jan (FZU-D) RID, ORCID
    Smrž, Martin (FZU-D) RID, ORCID
    Mocek, Tomáš (FZU-D) RID, ORCID, SAI
    Celkový počet autorů6
    Číslo článku18334
    Zdroj.dok.Scientific Reports. - : Nature Publishing Group - ISSN 2045-2322
    Roč. 12, č. 1 (2022)
    Poč.str.7 s.
    Jazyk dok.eng - angličtina
    Země vyd.DE - Německo
    Klíč. slovaTIPCL ; thermally-induced polarization ; Mueller matrix
    Vědní obor RIVBH - Optika, masery a lasery
    Obor OECDOptics (including laser optics and quantum optics)
    CEPEF15_006/0000674 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Způsob publikováníOpen access
    Institucionální podporaFZU-D - RVO:68378271
    UT WOS000877140500042
    EID SCOPUS85140941891
    DOI10.1038/s41598-022-22698-9
    AnotaceThe novel method of the thermally-induced polarization changes driven power losses (TIPCL) analysis in the complex laser systems has been developed. The measurement has been tested on the amplifier chain of the 100 J / 10 Hz laser system ‘Bivoj’ operated at HiLASE Centre. By the usage of the measured non-uniform Mueller matrix of the amplifier chain, the optimization of the ideal input and output polarization state has been calculated numerically. The results of the optimization have been applied to the laser system, thus reducing the TIPCL from originally observed more than 33% to 7.9% for CW beam and to 9% for pulsed laser beam, respectively. To the best of our knowledge, this result represents the most efficient TIPCL suppression method for complex laser systems so far. The method also allows the definition of the ideal fully polarized non-uniform pre-compensation of input beam consequently suffering from zero TIPCL.
    PracovištěFyzikální ústav
    KontaktKristina Potocká, potocka@fzu.cz, Tel.: 220 318 579
    Rok sběru2023
    Elektronická adresahttps://hdl.handle.net/11104/0335970
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.