Počet záznamů: 1  

Linear Energy Transfer (LET) dependence of graphene oxide dosimeter for different ionizing radiations

  1. 1.
    SYSNO ASEP0562823
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevLinear Energy Transfer (LET) dependence of graphene oxide dosimeter for different ionizing radiations
    Tvůrce(i) Torrisi, L. (IT)
    Silipigni, L. (IT)
    Cutroneo, Mariapompea (UJF-V) ORCID, RID, SAI
    Proverbio, E. (IT)
    Torrisi, A. (IT)
    Celkový počet autorů5
    Číslo článku111240
    Zdroj.dok.Vacuum. - : Elsevier - ISSN 0042-207X
    Roč. 203, SEP (2022)
    Poč.str.8 s.
    Forma vydáníTištěná - P
    Jazyk dok.eng - angličtina
    Země vyd.GB - Velká Británie
    Klíč. slovaGraphene oxide dosimetry ; Linear energy transfer (LET) ; XPS spectroscopy ; EDX analysis ; Raman spectroscopy
    Obor OECDNuclear physics
    CEPEF16_013/0001812 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    GA22-10536S GA ČR - Grantová agentura ČR
    Výzkumná infrastrukturaCANAM II - 90056 - Ústav jaderné fyziky AV ČR, v. v. i.
    Způsob publikováníOmezený přístup
    Institucionální podporaUJF-V - RVO:61389005
    UT WOS000865610800001
    EID SCOPUS85131736228
    DOI10.1016/j.vacuum.2022.111240
    AnotaceThe graphene oxide (GO) reduction by ionizing radiation is proportional to the absorbed dose due to the energy release which produces ionizations, deexcitations, chemical bonding breaking, radical formation and recombination, oxygen functional groups and water desorption. Thanks to this, GO can be employed as a dosimeter whose dose can be measured using different analysis techniques, such as Raman spectroscopy, X-ray diffraction (XRD) and Energy Dispersive X-ray (EDX) analysis based on the characteristic X-ray emission, X-ray photoelectron spectroscopy (XPS). To evaluate the GO reduction as a function of the Linear Energy Transfer (LET) of the used radiation, measurements have been performed with XPS and EDX to deduce the C/O atomic ratio versus the X-rays, electron and ion beam energy loss. Results indicate that a linear dependence on LET occurs, as will be presented and discussed.
    PracovištěÚstav jaderné fyziky
    KontaktMarkéta Sommerová, sommerova@ujf.cas.cz, Tel.: 266 173 228
    Rok sběru2023
    Elektronická adresahttps://doi.org/10.1016/j.vacuum.2022.111240
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.