Počet záznamů: 1  

Enhancement of the polydimethylsiloxane (PDMS) luminescence to develop a proton scintillator

  1. 1.
    SYSNO ASEP0562435
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevEnhancement of the polydimethylsiloxane (PDMS) luminescence to develop a proton scintillator
    Tvůrce(i) Torrisi, L. (IT)
    Silipigni, L. (IT)
    Torrisi, A. (IT)
    Havránek, Vladimír (UJF-V) RID, SAI, ORCID
    Cutroneo, Mariapompea (UJF-V) ORCID, RID, SAI
    Celkový počet autorů5
    Číslo článku167012
    Zdroj.dok.Nuclear Instruments & Methods in Physics Research Section A. - : Elsevier - ISSN 0168-9002
    Roč. 1039, SEP (2022)
    Poč.str.10 s.
    Forma vydáníTištěná - P
    Jazyk dok.eng - angličtina
    Země vyd.NL - Nizozemsko
    Klíč. slovaPolydimethylsiloxane ; Au-nanoparticles ; Graphene oxide microparticles ; Luminescence ; Scintillator ; Proton irradiation
    Obor OECDNuclear physics
    CEPGA19-02482S GA ČR - Grantová agentura ČR
    EF16_013/0001812 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Výzkumná infrastrukturaCANAM II - 90056 - Ústav jaderné fyziky AV ČR, v. v. i.
    Způsob publikováníOmezený přístup
    Institucionální podporaUJF-V - RVO:61389005
    UT WOS000861747900011
    EID SCOPUS85134561747
    DOI10.1016/j.nima.2022.167012
    AnotaceThe polydimethylsiloxane (PDMS) luminescence, induced by MeV proton beams, has been investigated in the pure and doped polymer. Gold nanoparticles (AuNPs) and graphene oxide microparticles (GO mu Ps) have been employed at low concentration (0.1 wt%) to modify the PDMS properties. Measurements have demonstrated that AuNPs enhance the PDMS luminescence, while GO mu Ps quench the polymer luminescence. The first ones, embedded into PDMS, produce a visible luminescence whose intensity is proportional to the absorbed proton dose. A linearity between the luminescence intensity and the proton absorbed dose is observed up to about 2.5 kGy, while at higher doses a luminescence saturation region shows up. The polymer can be employed to monitor in vacuum the proton beam spot size and shape and as a plastic scintillator dosimeter with peculiar elastic properties and high biocompatibility, as it will be presented and discussed.
    PracovištěÚstav jaderné fyziky
    KontaktMarkéta Sommerová, sommerova@ujf.cas.cz, Tel.: 266 173 228
    Rok sběru2023
    Elektronická adresahttps://doi.org/10.1016/j.nima.2022.167012
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.