Počet záznamů: 1  

Impact of electrolyte solution on electrochemical oxidation treatment of Escherichia coli K-12 by boron-doped diamond electrodes

  1. 1.
    SYSNO ASEP0561908
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevImpact of electrolyte solution on electrochemical oxidation treatment of Escherichia coli K-12 by boron-doped diamond electrodes
    Tvůrce(i) Budil, Jakub (FZU-D) ORCID, RID
    Szabó, Ondrej (FZU-D) ORCID, RID
    Lišková, P. (CZ)
    Štenclová, Pavla (FZU-D) ORCID
    Izsák, Tibor (FZU-D) ORCID
    Potocký, Štěpán (FZU-D) RID, ORCID
    Kromka, Alexander (FZU-D) RID, ORCID, SAI
    Celkový počet autorů7
    Zdroj.dok.Letters in Applied Microbiology. - : Wiley - ISSN 0266-8254
    Roč. 74, č. 6 (2022), s. 924-931
    Poč.str.8 s.
    Jazyk dok.eng - angličtina
    Země vyd.GB - Velká Británie
    Klíč. slovaboron-doped diamond ; chloride-based electrolyte ; chloride-free electrolyte ; Escherichia coli ; water disinfection
    Vědní obor RIVCG - Elektrochemie
    Obor OECDMicrobiology
    CEPEF16_019/0000760 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    LM2018110 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Způsob publikováníOpen access
    Institucionální podporaFZU-D - RVO:68378271
    UT WOS000765808700001
    EID SCOPUS85125927656
    DOI10.1111/lam.13687
    AnotaceWe studied the disinfection efficacy of boron-doped electrodes on Escherichia coli-contaminated water-based solutions in three different electrolytes, physiological solution (NaCl), phosphate buffer (PB), and phosphate buffer saline (PBS). The effect of the electrochemical oxidation treatment on the bacteria viability was studied by drop and spread plate cultivation methods, and supported by optical density measurements. We have found that bacterial suspensions in NaCl and PBS underwent a total inactivation of all viable bacteria within 10 min of the electrochemical treatment. By contrast, experiments performed in the PB showed a relatively minor decrease of viability by two orders of magnitude after 2 h of the treatment, which is almost comparable with the untreated control. The enhanced bacterial inactivation was assigned to reactive chlorine species, capable of penetrating the bacterial cytoplasmic membrane and killing bacteria from within.
    PracovištěFyzikální ústav
    KontaktKristina Potocká, potocka@fzu.cz, Tel.: 220 318 579
    Rok sběru2023
    Elektronická adresahttps://hdl.handle.net/11104/0334331
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.