An Electrochemical Sensor for Detection of Neuroblastoma Markers: Complexation Studies as a Tool for the Selection of a Suitable Receptor for Electrode Coating

  1. 1.
    SYSNO ASEP0559102
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevAn Electrochemical Sensor for Detection of Neuroblastoma Markers: Complexation Studies as a Tool for the Selection of a Suitable Receptor for Electrode Coating
    Tvůrce(i) Salvadori, Karolína (UCHP-M) RID, ORCID, SAI
    Páleš, Jakub Marián (UCHP-M)
    Shishkanova, T.V. (CZ)
    Trchová, M. (CZ)
    Fajgar, Radek (UCHP-M) RID, ORCID, SAI
    Matějka, P. (CZ)
    Cuřínová, Petra (UCHP-M) RID, SAI, ORCID
    Číslo článkue202200165
    Zdroj.dok.ChemPlusChem. - : Wiley - ISSN 2192-6506
    Roč. 87, č. 8 (2022)
    Poč.str.8 s.
    Jazyk dok.eng - angličtina
    Země vyd.DE - Německo
    Klíč. slovabiosensors ; electropolymerization ; host-guest chemistry ; neuroblastoma markers
    Obor OECDAnalytical chemistry
    CEPGA20-07833S GA ČR - Grantová agentura ČR
    Způsob publikováníOmezený přístup
    Institucionální podporaUCHP-M - RVO:67985858
    UT WOS000837730800001
    EID SCOPUS85135552513
    DOI10.1002/cplu.202200165
    AnotaceHomovanillate (HVA) and vanilmandelate (VMA) are recognized markers of diseases, including neuroblastoma. However, their detection in urine represents a challenging task due to the complexity of the matrix. Here, a design, synthesis and thorough investigation of polymerizable urea-based receptors interacting with HVA and VMA are reported. The selection of receptor with the best anion recognition properties for electrode coating is based on 1H NMR and UV-Vis complexation studies. The sensor is prepared by electropolymerization with progress monitoring by cyclic voltammetry. The deposited layer is characterized by IR and scanning electron microscopy. The obtained sensor shows an electrochemical impedance spectroscopy response to VMA with linear range 9.9×10-6 to 1.2×10-3 M and LOD of 3.4x10-6 M. The sensor selectivity was demonstrated by the determination of VMA level in the presence of 16 mM HVA and in artificial urine with and without phosphates, with standard deviations of 0.11, 0.17 and 0.09, respectively.