Počet záznamů: 1
Design and first tests of the S-3 detector of reactor antineutrinos
- 1.
SYSNO ASEP 0557506 Druh ASEP C - Konferenční příspěvek (mezinárodní konf.) Zařazení RIV D - Článek ve sborníku Název Design and first tests of the S-3 detector of reactor antineutrinos Tvůrce(i) Slavíčková, M. (CZ)
Belov, V. (RU)
Broulím, J. (CZ)
Brudanin, V. (RU)
Egorov, V. (RU)
Fajt, L. (CZ)
Fomina, M. (RU)
Hodák, R. (CZ)
Kazartsev, S. (RU)
Kruliš, Zdeněk (UMCH-V) RID, ORCID
Macko, M. (CZ)
Mašek, P. (CZ)
Michálková, Danuše (UMCH-V)
Petro, M. (CZ)
Přidal, P. (CZ)
Rukhadze, E. (CZ)
Shevchik, E. (RU)
Smolek, K. (CZ)
Slavíček, T. (CZ)
Štekl, I. (CZ)
Zhitnikov, I. (RU)Číslo článku 11011 Zdroj.dok. EPJ Web of Conferences, ANIMMA 2021 – Advancements in Nuclear Instrumentation Measurement Methods and their Applications, 253. - Les Ulis : E D P Sciences, 2021 - ISSN 2100-014X Poč.str. 5 s. Forma vydání Tištěná - P Akce Conference on Advancements in Nuclear Instrumentation Measurement Methods and their Applications (ANIMMA) Datum konání 21.06.2021 - 25.06.2021 Místo konání Prague Země CZ - Česká republika Typ akce WRD Jazyk dok. eng - angličtina Země vyd. FR - Francie Klíč. slova S3 experiment ; reactor neutrinos ; neutrino oscillations Vědní obor RIV CD - Makromolekulární chemie Obor OECD Polymer science Institucionální podpora UMCH-V - RVO:61389013 UT WOS 000788459400095 DOI 10.1051/epjconf/202125311011 Anotace The new experiment S3 devoted to the study of reactor antineutrinos was designed and constructed as a common activity of IEAP CTU in Prague and JINR (Dubna). The S3 detector is a compact, highly segmented polystyrene-based scintillating detector composed of 80 detector elements with a gadolinium neutron converter between elements layers. A positron and a neutron are produced in an inverse beta decay initiated with an electron antineutrino in the detector. A modular multi-channel fast ADC was developed for the data acquisition for the whole 80-channel S3 detector and the 4-channel cosmic veto system. The detector meets very strict safety rules of nuclear power plants and can be installed in a chamber located immediately under the reactor. The close vicinity from the reactor enables to study neutrino properties with a higher efficiency, to investigate neutrino oscillations at short baselines and try to verify the hypothesis of a sterile neutrino. The details of the design and construction of the S3 detector, as well as properties of the modular multi-channel fast ADC system, and first tests of the device are presented. Pracoviště Ústav makromolekulární chemie Kontakt Eva Čechová, cechova@imc.cas.cz ; Tel.: 296 809 358 Rok sběru 2023 Elektronická adresa https://www.epj-conferences.org/articles/epjconf/abs/2021/07/epjconf_animma2021_11011/epjconf_animma2021_11011.html
Počet záznamů: 1