Počet záznamů: 1
Personal exposure measurement during dental nanocomposite grinding
- 1.
SYSNO ASEP 0557156 Druh ASEP C - Konferenční příspěvek (mezinárodní konf.) Zařazení RIV O - Ostatní Název Personal exposure measurement during dental nanocomposite grinding Tvůrce(i) Ždímal, Vladimír (UCHP-M) RID, ORCID, SAI
Ondráčková, Lucie (UCHP-M) RID, ORCID, SAI
Ondráček, Jakub (UCHP-M) RID, ORCID, SAI
Schwarz, Jaroslav (UCHP-M) RID, ORCID, SAI
Bradna, P. (CZ)
Roubíčková, A. (CZ)
Pelclová, D. (CZ)
Rössnerová, Andrea (UEM-P) RIDZdroj.dok. Program a abstrakty konference s mezinárodní účastí Genetická toxikologie a prevence rakoviny. - Hlučín : Anna Vavrušová - Alisa Group, 2022 - ISBN 978-80-88038-10-8 Rozsah stran s. 41-42 Poč.str. 2 s. Forma vydání Tištěná - P Akce Konference s mezinárodní účastí Genetická toxikologie a prevence rakoviny Datum konání 02.05.2022 - 05.05.2022 Místo konání Telč Země CZ - Česká republika Typ akce EUR Jazyk dok. eng - angličtina Země vyd. CZ - Česká republika Klíč. slova dental treatment ; personal exposure ; nanocomposites Vědní obor RIV DN - Vliv životního prostředí na zdraví Obor OECD Occupational health CEP GA18-02079S GA ČR - Grantová agentura ČR GA22-08358S GA ČR - Grantová agentura ČR Institucionální podpora UCHP-M - RVO:67985858 ; UEM-P - RVO:68378041 Anotace The purpose of this study was to measure the personal exposure of each participant of the study and to compare the results with those of static monitoring. Personal nanoparticle sam-plers (PENS), which can simultaneously detect both nanoparticles (PM0.1) and respirable parti-cles (PMA), were used to determine personal exposure (Tsai et al., 2012). Area monitoring in-cluded measurement of mass concentrations using the Berner Low Pressure Impactor (BLPI 25/0.018 /2, Hauke GmbH, Gmunden, Austria) and the Low Volume Sampler (LV5, Sven Leckel Ingenieurbüro GmbH, Germany). The number concentrations and their size distributions were measured with the Scanning Mobility Particle Sizer (5MP5 3936, T5I Inc., USA) and the Aerody-namic Particle Sizer (APS 3321, TSI Inc., USA). Measurements with all of the above- mentioned instruments were performed in four shifts with six participants per shift. Each participant milled for 10 minutes and then remained in the room until the group finished the session, so the total exposure lasted about 70 minutes. Due to the high content of filler nanoparticles, the nanocom-posite Filtek Ultimate (body A2, 3M ESPE, USA) was selected for these measurements. Pracoviště Ústav chemických procesů Kontakt Eva Jirsová, jirsova@icpf.cas.cz, Tel.: 220 390 227 Rok sběru 2023 Elektronická adresa http://hdl.handle.net/11104/0331219
Počet záznamů: 1