Počet záznamů: 1  

Personal exposure measurement during dental nanocomposite grinding

  1. 1.
    SYSNO ASEP0557156
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVO - Ostatní
    NázevPersonal exposure measurement during dental nanocomposite grinding
    Tvůrce(i) Ždímal, Vladimír (UCHP-M) RID, ORCID, SAI
    Ondráčková, Lucie (UCHP-M) RID, ORCID, SAI
    Ondráček, Jakub (UCHP-M) RID, ORCID, SAI
    Schwarz, Jaroslav (UCHP-M) RID, ORCID, SAI
    Bradna, P. (CZ)
    Roubíčková, A. (CZ)
    Pelclová, D. (CZ)
    Rössnerová, Andrea (UEM-P) RID
    Zdroj.dok.Program a abstrakty konference s mezinárodní účastí Genetická toxikologie a prevence rakoviny. - Hlučín : Anna Vavrušová - Alisa Group, 2022 - ISBN 978-80-88038-10-8
    Rozsah strans. 41-42
    Poč.str.2 s.
    Forma vydáníTištěná - P
    AkceKonference s mezinárodní účastí Genetická toxikologie a prevence rakoviny
    Datum konání02.05.2022 - 05.05.2022
    Místo konáníTelč
    ZeměCZ - Česká republika
    Typ akceEUR
    Jazyk dok.eng - angličtina
    Země vyd.CZ - Česká republika
    Klíč. slovadental treatment ; personal exposure ; nanocomposites
    Vědní obor RIVDN - Vliv životního prostředí na zdraví
    Obor OECDOccupational health
    CEPGA18-02079S GA ČR - Grantová agentura ČR
    GA22-08358S GA ČR - Grantová agentura ČR
    Institucionální podporaUCHP-M - RVO:67985858 ; UEM-P - RVO:68378041
    AnotaceThe purpose of this study was to measure the personal exposure of each participant of the study and to compare the results with those of static monitoring. Personal nanoparticle sam-plers (PENS), which can simultaneously detect both nanoparticles (PM0.1) and respirable parti-cles (PMA), were used to determine personal exposure (Tsai et al., 2012). Area monitoring in-cluded measurement of mass concentrations using the Berner Low Pressure Impactor (BLPI 25/0.018 /2, Hauke GmbH, Gmunden, Austria) and the Low Volume Sampler (LV5, Sven Leckel Ingenieurbüro GmbH, Germany). The number concentrations and their size distributions were measured with the Scanning Mobility Particle Sizer (5MP5 3936, T5I Inc., USA) and the Aerody-namic Particle Sizer (APS 3321, TSI Inc., USA). Measurements with all of the above- mentioned instruments were performed in four shifts with six participants per shift. Each participant milled for 10 minutes and then remained in the room until the group finished the session, so the total exposure lasted about 70 minutes. Due to the high content of filler nanoparticles, the nanocom-posite Filtek Ultimate (body A2, 3M ESPE, USA) was selected for these measurements.
    PracovištěÚstav chemických procesů
    KontaktEva Jirsová, jirsova@icpf.cas.cz, Tel.: 220 390 227
    Rok sběru2023