Počet záznamů: 1  

Ultra-fast oscillation detection in EEG signal from deep-brain microelectrodes

  1. 1.
    SYSNO ASEP0556707
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevUltra-fast oscillation detection in EEG signal from deep-brain microelectrodes
    Tvůrce(i) Trávníček, Vojtěch (UPT-D) ORCID, RID, SAI
    Jurák, Pavel (UPT-D) RID, ORCID, SAI
    Cimbálník, J. (CZ)
    Klimeš, Petr (UPT-D) RID, ORCID, SAI
    Daniel, P. (CZ)
    Brázdil, M. (CZ)
    Celkový počet autorů7
    Zdroj.dok.43rd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC). - New York : IEEE, 2021 - ISBN 978-1-7281-1179-7
    Rozsah stran(2021), s. 265-268
    EdiceIEEE Engineering in Medicine and Biology Society Conference Proceedings
    Poč.str.4 s.
    Forma vydáníOnline - E
    AkceAnnual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC) /43./
    Datum konání01.11.2021 - 05.11.2021
    Místo konáníonline
    ZeměMX - Mexiko
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovahigh-frequency oscillations
    Vědní obor RIVFS - Lékařská zařízení, přístroje a vybavení
    Obor OECDMedical engineering
    CEPLTAUSA18056 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaUPT-D - RVO:68081731
    UT WOS000760910500062
    EID SCOPUS85122506059
    DOI10.1109/EMBC46164.2021.9629481
    AnotaceFor the last decades, ripples 80-200Hz (R)and fast ripples 200-500Hz (FR) were intensively studied as biomarkers of the epileptogenic zone (EZ). Recently, Very fast ripples 500-1000Hz (VFR) and ultra-fast ripples 1000-2000Hz (UFR) recorded using standard clinical macro electrodes have been shown to be more specific for EZ. High-sampled microelectrode recordings can bring new insights into this phenomenon of high frequency, multiunit activity. Unfortunately, visual detection of such events is extremely time consuming and unreliable. Here we present a detector of ultra-fast oscillations (UFO, >1kHz). In an example of two patients, we detected 951 UFOs which were more frequent in epileptic (8.6/min) vs. non-epileptic hippocampus (1.3/min). Our detection method can serve as a tool for exploring extremely high frequency events from microelectrode recordings.
    PracovištěÚstav přístrojové techniky
    KontaktMartina Šillerová, sillerova@ISIBrno.Cz, Tel.: 541 514 178
    Rok sběru2022
    Elektronická adresahttps://ieeexplore.ieee.org/document/9629481
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.