Počet záznamů: 1  

Fabrication of monolithic capillary columns with inner diameter 50-530 mu m employing a mixture of pentaerythritol tetraacrylate and polyhedral oligomeric silsesquioxane-methacrylate as crosslinkers

  1. 1.
    SYSNO ASEP0556696
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevFabrication of monolithic capillary columns with inner diameter 50-530 mu m employing a mixture of pentaerythritol tetraacrylate and polyhedral oligomeric silsesquioxane-methacrylate as crosslinkers
    Tvůrce(i) Planeta, Josef (UIACH-O) RID, ORCID
    Moravcová, Dana (UIACH-O) RID, ORCID
    Karásek, Pavel (UIACH-O) RID, ORCID
    Roth, Michal (UIACH-O) RID, ORCID
    Celkový počet autorů4
    Zdroj.dok.Journal of Separation Science. - : Wiley - ISSN 1615-9306
    Roč. 45, č. 17 (2022), s. 3256-3263
    Poč.str.8 s.
    Forma vydáníTištěná - P
    Jazyk dok.eng - angličtina
    Země vyd.DE - Německo
    Klíč. slovaliquid-chromatography ; inverse size-exclusion chromatography ; monoliths
    Vědní obor RIVCB - Analytická chemie, separace
    Obor OECDAnalytical chemistry
    Způsob publikováníOmezený přístup
    Institucionální podporaUIACH-O - RVO:68081715
    UT WOS000779885000001
    EID SCOPUS85127682682
    DOI10.1002/jssc.202200176
    AnotaceHighly crosslinked monolithic capillary columns with inner diameters in the range of 50-530 mu m were prepared by radical polymerization of pentaerythritol tetraacrylate, polyhedral oligomeric silsesquioxane-methacrylate, and n-octadecyl methacrylate in the presence of methanol, dodecyl alcohol, and polyethylene glycol lauryl ether. Columns were evaluated by inverse size-exclusion chromatography employing a set of polystyrene standards of narrow molecular-size distribution and by scanning electron microscopy. Chromatographic performance under reversed-phase conditions was also evaluated. The combination of two effective crosslinkers as pentaerythritol tetraacrylate and polyhedral oligomeric silsesquioxane-methacrylate in the polymerization mixture allows for the preparation of robust and efficient monolithic capillary columns within a fairly wide range of internal diameters.
    PracovištěÚstav analytické chemie
    KontaktIveta Drobníková, drobnikova@iach.cz, Tel.: 532 290 234
    Rok sběru2023
    Elektronická adresahttp://hdl.handle.net/11104/0330816
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.