Počet záznamů: 1  

High-temperature performance of self-healing SiC-YSZ thermal barrier coatings deposited by using various plasma spray concepts

  1. 1.
    SYSNO ASEP0555663
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevHigh-temperature performance of self-healing SiC-YSZ thermal barrier coatings deposited by using various plasma spray concepts
    Tvůrce(i) Hassanzadeh, M. (IR)
    Sokołowski, P. (PL)
    Mušálek, Radek (UFP-V) RID, ORCID
    Medřický, Jan (UFP-V) RID
    Csáki, Štefan (UFP-V) ORCID
    Celkový počet autorů5
    Zdroj.dok.Thermal Spray 2021: Proceedings from the International Thermal Spray Conference. - Materials Park : ASM International, 2021 - ISBN 9781713831303
    Rozsah strans. 18-22
    Poč.str.5 s.
    Forma vydáníOnline - E
    AkceInternational Thermal Spray Conference 2021
    Datum konání24.05.2021 - 28.05.2021
    Místo konáníonline
    ZeměCZ - Česká republika
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovaSiC-YSZ ; thermal barrier ; coatings
    Vědní obor RIVJH - Keramika, žáruvzdorné materiály a skla
    Obor OECDCeramics
    CEPGA19-10246S GA ČR - Grantová agentura ČR
    Institucionální podporaUFP-V - RVO:61389021
    DOI10.31399/asm.cp.itsc2021p0018
    AnotaceIn this study, a novel self-healing concept is considered in order to increase the lifetime of thermal barrier coatings (TBCs) in modern gas turbines. For that purpose, SiC healing particles were introduced to conventional 8YSZ topcoats by using various plasma spray concepts, i.e., composite or multilayered coatings. All topcoats were sprayed by SG-100 plasma torch on previously deposited NiCrAlY bondcoats produced by conventional atmospheric plasma spraying. Coatings were subjected to thermal conductivity measurements by laser flash method up to 1000°C, isothermal oxidation testing up to 200h at 1100°C and finally thermal cyclic fatigue (TCF) lifetime testing at 1100°C. Microstructural coating evaluation was performed by scanning electronic microscope (SEM), in the as-produced and post high-temperature tested states. This was done to analyze the self-healing phenomena and its influence on the high-temperature performance of the newly developed TBCs.
    PracovištěÚstav fyziky plazmatu
    KontaktVladimíra Kebza, kebza@ipp.cas.cz, Tel.: 266 052 975
    Rok sběru2022
    Elektronická adresahttps://dl.asminternational.org/itsc/proceedings-abstract/ITSC%202021/83881/18/16768
Počet záznamů: 1  