High-power laser testing of calcium-phosphate-based bioresorbable optical fibers
- 1.
SYSNO ASEP 0553135 Druh ASEP J - Článek v odborném periodiku Zařazení RIV J - Článek v odborném periodiku Poddruh J Článek ve WOS Název High-power laser testing of calcium-phosphate-based bioresorbable optical fibers Tvůrce(i) Peterka, Pavel (URE-Y) RID
Pugliese, D. (IT)
Jiříčková, Bára (URE-Y)
Boetti, N.G. (IT)
Turčičová, Hana (FZU-D) RID, ORCID
Mirza, M. Inam (FZU-D) ORCID
Borodkin, Andrei (URE-Y)
Milanese, D. (IT)Celkový počet autorů 8 Zdroj.dok. Optical Materials Express. - : Optical Society of America - ISSN 2159-3930
Roč. 11, č. 7 (2021), s. 2049-2058Poč.str. 10 s. Forma vydání Tištěná - P Jazyk dok. eng - angličtina Země vyd. US - Spojené státy americké Klíč. slova Optical fibers ; Calcium phosphate ; Transmissions Vědní obor RIV BH - Optika, masery a lasery Obor OECD Optics (including laser optics and quantum optics) Vědní obor RIV – spolupráce Fyzikální ústav - Optika, masery a lasery CEP GA19-03141S GA ČR - Grantová agentura ČR EF15_006/0000674 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy LM2015086 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy LO1602 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy Způsob publikování Open access Institucionální podpora URE-Y - RVO:67985882 ; FZU-D - RVO:68378271 UT WOS 000668925100005 EID SCOPUS 85107861380 DOI 10.1364/OME.428490 Anotace Silica optical fibers are employed in endoscopy and related minimally invasive medical methods thanks to their good transparency and flexibility. Although silicon oxide is a biocompatible material, its use involves a serious health risk due to its fragility and the fact that potential fiber fragments can freely move inside the body without the possibility of being detected by conventional methods such as X-ray imaging. A possible solution to this issue can be the development of optical fibers based on bioresorbable (i.e., biodegradable and biocompatible) materials, which exhibit the important benefit of not having to be explanted after their functionality has expired. The optical power transmission tests of recently developed single-mode (SM) and multi-mode (MM) bioresorbable optical fibers based on calcium-phosphate glasses (CPGs) are here reported. A continuous-wave (CW) fiber laser at 1080 nm with output power up to 13 W and picosecond laser sources at 515 and 1030 nm with MW pulse peak power were used to test the transmission capabilities of the CPG fibers. No degradation of the CPG fibers transmission under long-term illumination by CW laser was observed. A laser-induced damage threshold (LIDT) at a fluence higher than 0.17 J/cm(2) was assessed with the picosecond laser sources Pracoviště Ústav fotoniky a elektroniky Kontakt Petr Vacek, vacek@ufe.cz, Tel.: 266 773 413, 266 773 438, 266 773 488 Rok sběru 2022 Elektronická adresa https://doi.org/10.1364/OME.428490
Počet záznamů: 1