Počet záznamů: 1  

A complex evaluation of the in-vivo biocompatibility and degradation of an extruded ZnMgSr absorbable alloy implanted into rabbit bones for 360 days

  1. 1.
    SYSNO ASEP0549687
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevA complex evaluation of the in-vivo biocompatibility and degradation of an extruded ZnMgSr absorbable alloy implanted into rabbit bones for 360 days
    Tvůrce(i) Klíma, K. (CZ)
    Ulmann, D. (CZ)
    Bartoš, M. (CZ)
    Španko, M. (CZ)
    Dušková, J. (CZ)
    Vrbová, R. (CZ)
    Pinc, Jan (FZU-D) ORCID
    Kubásek, J. (CZ)
    Vlk, M. (CZ)
    Ulmannová, T. (CZ)
    Foltán, R. (CZ)
    Brizman, E. (CZ)
    Drahoš, M. (CZ)
    Beňo, M. (CZ)
    Machoň, V. (CZ)
    Čapek, Jaroslav (FZU-D) ORCID
    Celkový počet autorů16
    Číslo článku13444
    Zdroj.dok.International Journal of Molecular Sciences. - : MDPI
    Roč. 22, Dec (2021)
    Poč.str.24 s.
    Jazyk dok.eng - angličtina
    Země vyd.CH - Švýcarsko
    Klíč. slovaabsorbable metals ; in vivo ; magnesium ; zinc ; strontium ; toxicity ; biocompatibility ; systemic reactions ; alloy accumulation ; internal organs
    Vědní obor RIVJG - Hutnictví, kovové materiály
    Obor OECDMaterials engineering
    CEPLM2018110 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    EF16_019/0000760 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    GA18-06110S GA ČR - Grantová agentura ČR
    Způsob publikováníOpen access
    Institucionální podporaFZU-D - RVO:68378271
    UT WOS000737886300001
    EID SCOPUS85121043397
    DOI10.3390/ijms222413444
    AnotaceIn this study, we analyzed an extruded Zn-0.8Mg-0.2Sr (wt.%) absorbable/biodegradable alloy on a rabbit model. Screws made of this alloy were implanted into the rabbit tibia. After 120, 240, and 360 days, we tested the toxicity at the site of implantation and also within the vital organs. The results were compared with a control group, implanted with a Ti-based screw and sacrificed after 360 days. The samples were analyzed using X-ray, micro-CT, and a scanning electron microscope. Chemical analysis revealed only small concentrations of zinc, strontium, and magnesium in the liver, kidneys, and brain. Histologically, the alloy was verified to possess very good biocompatibility after 360 days. We did not observe raised levels of Sr, Zn, or Mg in any of the vital organs when compared with the Ti group at 360 days. The material was found to slowly degrade in vivo, forming solid corrosion products on its surface.
    PracovištěFyzikální ústav
    KontaktKristina Potocká, potocka@fzu.cz, Tel.: 220 318 579
    Rok sběru2022
    Elektronická adresahttp://hdl.handle.net/11104/0325631
Počet záznamů: 1  