Počet záznamů: 1  

Dosimetric Optimization of a Laser-Driven Irradiation Facility Using the G4-ELIMED Application

  1. 1.
    SYSNO ASEP0549657
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevDosimetric Optimization of a Laser-Driven Irradiation Facility Using the G4-ELIMED Application
    Tvůrce(i) Barba, S. M. (CH)
    Schillaci, Francesco (FZU-D) ORCID
    Catalano, R. (IT)
    Petringa, Giada (FZU-D) ORCID
    Margarone, Daniele (FZU-D) RID, ORCID
    Cirrone, G. A. P. (IT)
    Celkový počet autorů6
    Číslo článku9823
    Zdroj.dok.Applied Sciences-Basel. - : MDPI
    Roč. 11, č. 21 (2021)
    Poč.str.11 s.
    Jazyk dok.eng - angličtina
    Země vyd.CH - Švýcarsko
    Klíč. slovaMonte Carlo simulations ; Geant4 ; laser-accelerated ion beams
    Vědní obor RIVBF - Elementární částice a fyzika vys. energií
    Obor OECDParticles and field physics
    CEPEF16_019/0000789 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Výzkumná infrastrukturaELI Beamlines III - 90141 - Fyzikální ústav AV ČR, v. v. i.
    Způsob publikováníOpen access
    Institucionální podporaFZU-D - RVO:68378271
    UT WOS000723189200001
    EID SCOPUS85117707591
    DOI10.3390/app11219823
    AnotaceELIMED has been developed and installed at ELI beamlines as a part of the ELIMAIA beamline to transport, monitor, and use laser-driven ion beams suitable for multidisciplinary applications, including biomedical ones. This paper aims to investigate the feasibility to perform radiobiological experiments using laser-accelerated proton beams with intermediate energies (up to 30 MeV). To reach this goal, we simulate a proton source based on experimental data like the ones expected to be available in the first phase of ELIMED commissioning by using the G4-ELIMED application (an application based on the Geant4 toolkit that simulates the full ELIMED beamline). This allows the study of transmission efficiency and the final characteristics of the proton beam at the sample irradiation point. The Energy Selector System is used as an active energy modulator to obtain the desired beam features in a relatively short irradiation time (around 6 min).
    PracovištěFyzikální ústav
    KontaktKristina Potocká, potocka@fzu.cz, Tel.: 220 318 579
    Rok sběru2022
    Elektronická adresahttp://hdl.handle.net/11104/0325626
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.