Počet záznamů: 1
LIPSS‑based functional surfaces produced by multi‑beam nanostructuring with 2601 beams and real‑time thermal processes measurement
- 1.
SYSNO ASEP 0549579 Druh ASEP J - Článek v odborném periodiku Zařazení RIV J - Článek v odborném periodiku Poddruh J Článek ve WOS Název LIPSS‑based functional surfaces produced by multi‑beam nanostructuring with 2601 beams and real‑time thermal processes measurement Tvůrce(i) Hauschwitz, Petr (FZU-D) ORCID
Martan, J. (CZ)
Bičišťová, Radka (FZU-D) ORCID
Beltrami, C. (CZ)
Moskal, D. (CZ)
Brodsky, A. (IL)
Kaplan, N. (IL)
Mužík, Jiří (FZU-D) ORCID
Štěpánková, Denisa (FZU-D) ORCID
Brajer, Jan (FZU-D) ORCID
Rostohar, Danijela (FZU-D) ORCID
Kopeček, Jaromír (FZU-D) RID, ORCID
Prokešová, L. (CZ)
Honner, M. (CZ)
Lang, V. (CZ)
Smrž, Martin (FZU-D) RID, ORCID
Mocek, Tomáš (FZU-D) RID, ORCID, SAICelkový počet autorů 17 Číslo článku 22944 Zdroj.dok. Scientific Reports. - : Nature Publishing Group - ISSN 2045-2322
Roč. 11, č. 1 (2021)Poč.str. 10 s. Jazyk dok. eng - angličtina Země vyd. GB - Velká Británie Klíč. slova ultrashort high-energy pulsed laser ; diffractive optical element ; LIPSS Vědní obor RIV BH - Optika, masery a lasery Obor OECD Optics (including laser optics and quantum optics) CEP EF15_006/0000674 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy LO1602 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy Způsob publikování Open access Institucionální podpora FZU-D - RVO:68378271 UT WOS 000722710200064 EID SCOPUS 85119892388 DOI 10.1038/s41598-021-02290-3 Anotace A combination of the ultrashort high-energy pulsed las. syst. with exceptional beam quality and a novel DOE enables simultaneous production of 2601 spots organized in the square-shaped 1×1mm matrix in less than 0.01ms.By adjusting the las. and processing parameters each spot can contain LIPSS,ripples,including high-spatial freq. LIPSS and low-spatial freq. LIPSS.DOE placed before galvanometric scanner allows easy integration and stitching of the pattern over larger areas.The LIPSS formation was monitored for using fast infrared radiometry for verification of real-time quality control possibilities.During the LIPSS fabrication,solidification plateaus were observed after each las. pulse,which enables process control by monitoring heat accumulation or plateau length using a new signal derivation approach.Analysis of solidification plateaus after each las. pulse enabled dynamic calibration of the measurement. Pracoviště Fyzikální ústav Kontakt Kristina Potocká, potocka@fzu.cz, Tel.: 220 318 579 Rok sběru 2022 Elektronická adresa http://hdl.handle.net/11104/0325582
Počet záznamů: 1