Počet záznamů: 1  

LIPSS‑based functional surfaces produced by multi‑beam nanostructuring with 2601 beams and real‑time thermal processes measurement

  1. 1.
    SYSNO ASEP0549579
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevLIPSS‑based functional surfaces produced by multi‑beam nanostructuring with 2601 beams and real‑time thermal processes measurement
    Tvůrce(i) Hauschwitz, Petr (FZU-D) ORCID
    Martan, J. (CZ)
    Bičišťová, Radka (FZU-D) ORCID
    Beltrami, C. (CZ)
    Moskal, D. (CZ)
    Brodsky, A. (IL)
    Kaplan, N. (IL)
    Mužík, Jiří (FZU-D) ORCID
    Štěpánková, Denisa (FZU-D) ORCID
    Brajer, Jan (FZU-D) ORCID
    Rostohar, Danijela (FZU-D) ORCID
    Kopeček, Jaromír (FZU-D) RID, ORCID
    Prokešová, L. (CZ)
    Honner, M. (CZ)
    Lang, V. (CZ)
    Smrž, Martin (FZU-D) RID, ORCID
    Mocek, Tomáš (FZU-D) RID, ORCID, SAI
    Celkový počet autorů17
    Číslo článku22944
    Zdroj.dok.Scientific Reports. - : Nature Publishing Group - ISSN 2045-2322
    Roč. 11, č. 1 (2021)
    Poč.str.10 s.
    Jazyk dok.eng - angličtina
    Země vyd.GB - Velká Británie
    Klíč. slovaultrashort high-energy pulsed laser ; diffractive optical element ; LIPSS
    Vědní obor RIVBH - Optika, masery a lasery
    Obor OECDOptics (including laser optics and quantum optics)
    CEPEF15_006/0000674 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    LO1602 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Způsob publikováníOpen access
    Institucionální podporaFZU-D - RVO:68378271
    UT WOS000722710200064
    EID SCOPUS85119892388
    DOI10.1038/s41598-021-02290-3
    AnotaceA combination of the ultrashort high-energy pulsed las. syst. with exceptional beam quality and a novel DOE enables simultaneous production of 2601 spots organized in the square-shaped 1×1mm matrix in less than 0.01ms.By adjusting the las. and processing parameters each spot can contain LIPSS,ripples,including high-spatial freq. LIPSS and low-spatial freq. LIPSS.DOE placed before galvanometric scanner allows easy integration and stitching of the pattern over larger areas.The LIPSS formation was monitored for using fast infrared radiometry for verification of real-time quality control possibilities.During the LIPSS fabrication,solidification plateaus were observed after each las. pulse,which enables process control by monitoring heat accumulation or plateau length using a new signal derivation approach.Analysis of solidification plateaus after each las. pulse enabled dynamic calibration of the measurement.
    PracovištěFyzikální ústav
    KontaktKristina Potocká, potocka@fzu.cz, Tel.: 220 318 579
    Rok sběru2022
    Elektronická adresahttp://hdl.handle.net/11104/0325582
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.