Development and measurement of gas sensors based on diamond and transition metal dichalcogenide materials

  1. 1.
    SYSNO ASEP0546604
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevDevelopment and measurement of gas sensors based on diamond and transition metal dichalcogenide materials
    Tvůrce(i) Kočí, Michal (FZU-D) ORCID
    Izsák, T. (SK)
    Vanko, M. (SK)
    Sojková, M. (SK)
    Husák, M. (CZ)
    Kromka, Alexander (FZU-D) RID, ORCID, SAI
    Celkový počet autorů6
    Zdroj.dok.Proceedings of ADEPT - ADEPT 2021. - Žilina : University of Žilina, 2021 / Jandura D. ; Maniaková P. ; Lettrichová I. ; Kováč, jr. J. - ISBN 978-80-554-1806-3
    Rozsah strans. 115-118
    Poč.str.4 s.
    Forma vydáníOnline - E
    Akce9th International Conference on Advances in Electronic and Photonic Technologies - ADEPT 2021
    Datum konání20.09.2021 - 23.09.2021
    Místo konáníPodbanské
    ZeměSK - Slovensko
    Typ akceEUR
    Jazyk dok.eng - angličtina
    Země vyd.SK - Slovensko
    Klíč. slovananocrystalline diamond (NCD) ; transition metal dichalcogenide (TMD) ; gas detectors
    Vědní obor RIVJB - Senzory, čidla, měření a regulace
    Obor OECDMaterials engineering
    CEPEF16_019/0000760 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    LM2018110 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaFZU-D - RVO:68378271
    AnotaceGas sensing properties of a nanocrystalline diamond with hydrogen-terminated surface (H-NCD) and a transition metal dichalcogenide (TMD) are investigated as conductivity sensors employing device design with built-in interdigital metal electrode structures. The TMDs were prepared by a carbide-free one-zone sulfurization method directly on the SiO2/Si or NCD/Si substrates. On the individual level, the sensors showed a notable electrical response to the examined gas types, i.e., oxidizing (NO2) and reducing (NH3) gases. For reference, commercially available sensor was used (conductive SnO2 or infra-red type). Advantageously, it was found that the NCD/TMD heterostructure results in enhanced signal stability and gas sensing response at room temperature compared to both bare TMD and H-NCD layers.