Počet záznamů: 1
Conceptual design of the COMPASS-U control systems
- 1.
SYSNO ASEP 0544100 Druh ASEP J - Článek v odborném periodiku Zařazení RIV J - Článek v odborném periodiku Poddruh J Článek ve WOS Název Conceptual design of the COMPASS-U control systems Tvůrce(i) Havránek, Aleš (UFP-V) ORCID
Bogár, Ondrej (UFP-V) ORCID
Fridrich, David (UFP-V)
Hanák, Ivo (UFP-V)
Majer, Tomáš (UFP-V)
Burant, Jiří (UFP-V)
Havlíček, Josef (UFP-V) RID, ORCID
Vondráček, Petr (UFP-V) RID, ORCID
Komm, Michael (UFP-V) RID, ORCID
Hron, Martin (UFP-V) RID, ORCID
Pánek, Radomír (UFP-V) RIDCelkový počet autorů 11 Číslo článku 112550 Zdroj.dok. Fusion Engineering and Design. - : Elsevier - ISSN 0920-3796
Roč. 170, September (2021)Poč.str. 9 s. Jazyk dok. eng - angličtina Země vyd. CH - Švýcarsko Klíč. slova codac ; COMPASS-U tokamak ; Control systems ; Data acquisition Vědní obor RIV BL - Fyzika plazmatu a výboje v plynech Obor OECD Fluids and plasma physics (including surface physics) CEP EF16_019/0000768 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy LM2018117 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy Způsob publikování Omezený přístup Institucionální podpora UFP-V - RVO:61389021 UT WOS 000684310600002 EID SCOPUS 85103766784 DOI 10.1016/j.fusengdes.2021.112550 Anotace The COMPASS-U tokamak is an advanced and more complicated successor of the COMPASS tokamak. Almost all main technological parts will be different. Both the higher performance of COMPASS-U and the increased number of parts and systems lead to a higher risk of failure. Therefore, new control systems must be developed regarding handling dangerous situations and integrating new systems. The COMPASS-U also opens the opportunity to make significant changes in the current systems based on the experience gained from COMPASS operation and to upgrade the systems to nowadays technologies. This article focuses on the conceptual design of the COMPASS-U control systems. It shows all CODAC (Control, Data Access, and Communication) systems their purpose, functionality, operation principle, interaction, and main used technologies. The COMPASS-U will use EPICS (Experimental Physics and Industrial Control System) for Slow control and supervision system. The real-time plasma control system will utilize MARTe2 (Multi-threaded Application Real-Time executor). The base control loop period of the Real-time plasma control system will be 50 μs as of COMPASS. Pracoviště Ústav fyziky plazmatu Kontakt Vladimíra Kebza, kebza@ipp.cas.cz, Tel.: 266 052 975 Rok sběru 2022 Elektronická adresa https://www.sciencedirect.com/science/article/pii/S0920379621003264?via%3Dihub
Počet záznamů: 1