Počet záznamů: 1  

Runaway electron diagnostics using silicon strip detector

  1. 1.
    SYSNO ASEP0538151
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevRunaway electron diagnostics using silicon strip detector
    Tvůrce(i) Novotný, L. (CZ)
    Čeřovský, Jaroslav (UFP-V)
    Dhyani, P. (CZ)
    Ficker, O. (CZ)
    Havránek, M. (CZ)
    Hejtmánek, M. (CZ)
    Janoška, Z. (CZ)
    Kafka, V. (CZ)
    Kulkov, S. (CZ)
    Marčišovská, M. (CZ)
    Marcisovský, M. (CZ)
    Neue, G. (CZ)
    Svihra, P. (CZ)
    Svoboda, V. (CS)
    Tomášek, L. (CZ)
    Tunkl, M. (CZ)
    Vrba, V. (CZ)
    Celkový počet autorů17
    Číslo článkuC07015
    Zdroj.dok.Journal of Instrumentation. - : Institute of Physics Publishing - ISSN 1748-0221
    Roč. 15, č. 7 (2020)
    Poč.str.9 s.
    Jazyk dok.eng - angličtina
    Země vyd.GB - Velká Británie
    Klíč. slovaRunaway electrons ; silicon strip detector
    Vědní obor RIVBL - Fyzika plazmatu a výboje v plynech
    Obor OECDFluids and plasma physics (including surface physics)
    CEPGA18-02482S GA ČR - Grantová agentura ČR
    Způsob publikováníOmezený přístup
    Institucionální podporaUFP-V - RVO:61389021
    UT WOS000551901300015
    EID SCOPUS85088038025
    DOI10.1088/1748-0221/15/07/C07015
    AnotaceWe present a proof-of-principle measurement of runaway electrons in a small tokamak using a silicon strip detector. The detector was placed inside the diagnostic port of the tokamak vessel and detected the runaway electron signal directly. The measured signal was compared to the signal provided by other tokamak diagnostics, especially the hard X-ray scintillation detector, which detects secondary photons created by interaction of accelerated electrons with tokamak walls (indirect detection of runaway electrons). The preliminary results show that when not saturated, direct detection with a segmented silicon strip detector provides promising new diagnostic information including spatial and temporal distribution of the runaway electron beam, and the measurement results are in good agreement with hard X-ray measurements with a scintillation detector.
    PracovištěÚstav fyziky plazmatu
    KontaktVladimíra Kebza, kebza@ipp.cas.cz, Tel.: 266 052 975
    Rok sběru2021
    Elektronická adresahttps://iopscience.iop.org/article/10.1088/1748-0221/15/07/C07015/pdf
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.