Počet záznamů: 1  

Synthesis, characterisation and supercritical fluid chromatography enantioseparation of new liquid crystalline materials

  1. 1.
    SYSNO ASEP0536056
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevSynthesis, characterisation and supercritical fluid chromatography enantioseparation of new liquid crystalline materials
    Tvůrce(i) Urbańska, M. (PL)
    Vaňkátová, Petra (FZU-D) ORCID, RID
    Kubíčková, A. (CZ)
    Kalíková, K. (CZ)
    Celkový počet autorů4
    Zdroj.dok.Liquid Crystals. - : Taylor & Francis - ISSN 0267-8292
    Roč. 47, č. 12 (2020), s. 1832-1843
    Poč.str.12 s.
    Jazyk dok.eng - angličtina
    Země vyd.GB - Velká Británie
    Klíč. slovaliquid crystal ; synthesis ; racemic mixtures ; enantioseparation ; supercritical fluid chromatography
    Vědní obor RIVCB - Analytická chemie, separace
    Obor OECDAnalytical chemistry
    Způsob publikováníOmezený přístup
    Institucionální podporaFZU-D - RVO:68378271
    UT WOS000527426800001
    EID SCOPUS85082427490
    DOI10.1080/02678292.2020.1733684
    AnotaceEnantiomeric excess (EE) highly affects the mesomorphic properties of mesogens containing centre of chirality. Thus, there is need of methods for evaluation of the EE of newly synthesised compounds as it should be considered when discussing the mesomorphic properties. We report synthesis and characterisation of ten new racemic mixtures based on (R,S)-3-octanol, which were used to develop an enantioseparation method that can be used for the assessment of the EE of chiral liquid crystals and their mixtures. The mesomorphic properties of novel materials were measured. Supercritical fluid chromatography with polysaccharide-based chiral stationary phases was used to develop reliable method for enantioseparation of the materials. A complete separation of (S) and (R) enantiomers with resolution values higher than 2.0 was obtained for all materials using simple mobile phase. The enantiomer elution order was assessed using pure (S) enantiomers of all materials. For all materials (R) enantiomer elutes first which is advantageous for use as optical purity control of newly synthesised (S) enantiomers.
    PracovištěFyzikální ústav
    KontaktKristina Potocká, potocka@fzu.cz, Tel.: 220 318 579
    Rok sběru2021
    Elektronická adresahttps://doi.org/10.1080/02678292.2020.1733684
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.