Počet záznamů: 1  

Experimental study on compression of 216-W laser pulses below 2 ps at 1030 nm with chirped volume Bragg grating

  1. 1.
    SYSNO ASEP0533949
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevExperimental study on compression of 216-W laser pulses below 2 ps at 1030 nm with chirped volume Bragg grating
    Tvůrce(i) Štěpánková, Denisa (FZU-D) ORCID
    Mužík, Jiří (FZU-D) ORCID
    Novák, Ondřej (FZU-D) RID, ORCID
    Roškot, Lukáš (FZU-D) ORCID
    Smirnov, V. (US)
    Glebov, L. (US)
    Jelínek, M. (CZ)
    Smrž, Martin (FZU-D) RID, ORCID
    Lucianetti, Antonio (FZU-D) RID, ORCID
    Mocek, Tomáš (FZU-D) RID, ORCID, SAI
    Celkový počet autorů10
    Zdroj.dok.Applied Optics . - : Optical Society of America - ISSN 1559-128X
    Roč. 59, č. 26 (2020), s. 7938-7944
    Poč.str.7 s.
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovachirped volume Bragg grating (CVBG) pulse compressor ; Yb:YAG thin-disk laser
    Vědní obor RIVBH - Optika, masery a lasery
    Obor OECDOptics (including laser optics and quantum optics)
    CEPEF15_006/0000674 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    LO1602 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Způsob publikováníOpen access
    Institucionální podporaFZU-D - RVO:68378271
    UT WOS000571484700026
    EID SCOPUS85091807297
    DOI10.1364/AO.400415
    AnotaceWe report on the characterization of a high-power, chirped volume Bragg grating (CVBG) pulse compressor. It includes measurements of the CVBG’s diffraction efficiency, beam profile, beam quality (M2 parameter), pulse spectrum, the CVBG’s temperature, and the thermal lens. These parameters were monitored for a wide range of input laser powers and with different clamping forces applied on the CVBG. This analysis was performed with a CPA-based Yb:YAG thin-disk laser system operating at a wavelength of 1030 nm, a 92 kHz repetition rate, 2 ps pulse duration, and an average output power after compression of 216 W (270 W uncompressed), which is, to the best of our knowledge, the highest value reported to date using this pulse compression technique.
    PracovištěFyzikální ústav
    KontaktKristina Potocká, potocka@fzu.cz, Tel.: 220 318 579
    Rok sběru2021
    Elektronická adresahttp://hdl.handle.net/11104/0312176
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.