Počet záznamů: 1
Effect of the gas puff location on the divertor plasma properties in COMPASS tokamak
- 1.
SYSNO ASEP 0531277 Druh ASEP J - Článek v odborném periodiku Zařazení RIV J - Článek v odborném periodiku Poddruh J Článek ve WOS Název Effect of the gas puff location on the divertor plasma properties in COMPASS tokamak Tvůrce(i) Dimitrova, Miglena (UFP-V) ORCID
Tomeš, Matěj (UFP-V)
Popov, Tsv. (BG)
Dejarnac, Renaud (UFP-V) RID, ORCID
Stöckel, Jan (UFP-V) RID
Adámek, Jiří (UFP-V) RID, ORCID
Vasileva, E. (BG)
Hron, Martin (UFP-V) RID, ORCID
Pánek, Radomír (UFP-V) RIDCelkový počet autorů 9 Číslo článku 012003 Zdroj.dok. Journal of Physics: Conference Series. - : Institute of Physics Publishing - ISSN 1742-6588
Roč. 17, č. 1492 (2020)Poč.str. 6 s. Jazyk dok. eng - angličtina Země vyd. GB - Velká Británie Klíč. slova COMPASS ; tokamak ; divertor Vědní obor RIV BL - Fyzika plazmatu a výboje v plynech Obor OECD Fluids and plasma physics (including surface physics) CEP LM2015045 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy 8D15001 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy EF16_019/0000768 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy Způsob publikování Open access Institucionální podpora UFP-V - RVO:61389021 UT WOS 000593712900003 DOI 10.1088/1742-6596/1492/1/012003 Anotace Langmuir probes are used to study the plasma parameters in the divertor during deuterium gas puff injection on the high- (HFS) or low-field sides (LFS). The probe data were processed to evaluate the plasma potential and the electron temperatures and densities. A difference was found in the plasma parameters depending on the gas puff location.
In the case of a gas puff on the LFS, the plasma parameters changed vastly, mainly in the inner divertor the plasma potential, the ion saturation-current density and the electron temperature dropped. After the gas puff, the electron temperature changed from 10-15 eV down to within the 5-9 eV range. As a result, the parallel heat-flux density decreased. At the same time, in the outer divertor the plasma parameters remained the same. We thus concluded that using a gas puff on the LFS will facilitate reaching a detachment regime by increasing the density of puffed neutrals.
When the deuterium gas puff was on the HFS, the plasma parameters in the divertor region remained almost the same before and during the puff. The electron temperature decreased with just few eV as a result of the increased amount of gas in the vacuum chamber.
Pracoviště Ústav fyziky plazmatu Kontakt Vladimíra Kebza, kebza@ipp.cas.cz, Tel.: 266 052 975 Rok sběru 2021 Elektronická adresa https://iopscience.iop.org/article/10.1088/1742-6596/1492/1/012003/pdf
Počet záznamů: 1