Systematic errors in tokamak magnetic equilibrium reconstruction: A study of EFIT++ at tokamak COMPASS

  1. 1.
    SYSNO ASEP0531252
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevSystematic errors in tokamak magnetic equilibrium reconstruction: A study of EFIT++ at tokamak COMPASS
    Tvůrce(i) Jiráková, Kateřina (UFP-V)
    Kovanda, O. (CZ)
    Adámek, Jiří (UFP-V) RID, ORCID
    Komm, Michael (UFP-V) RID, ORCID
    Seidl, Jakub (UFP-V) RID
    Celkový počet autorů5
    Číslo článkuC11020
    Zdroj.dok.Journal of Instrumentation. - : Institute of Physics Publishing - ISSN 1748-0221
    Roč. 14, č. 11 (2019)
    Poč.str.7 s.
    Jazyk dok.eng - angličtina
    Země vyd.GB - Velká Británie
    Klíč. slovaAnalysis and statistical methods ; Plasma diagnostics ; probes
    Vědní obor RIVBL - Fyzika plazmatu a výboje v plynech
    Obor OECDFluids and plasma physics (including surface physics)
    CEPGA19-15229S GA ČR - Grantová agentura ČR
    8D15001 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    LM2015045 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Způsob publikováníOmezený přístup
    Institucionální podporaUFP-V - RVO:61389021
    UT WOS000507588300020
    EID SCOPUS85082806934
    DOI10.1088/1748-0221/14/11/C11020
    AnotaceUncertainties and errors in magnetic equilibrium reconstructions are a wide-spread problem in interpreting experimental data measured in the tokamak edge. This study demonstrates errors in EFIT++ reconstructions performed on the COMPASS tokamak by comparing the outer midplane separatrix position to the Velocity Shear Layer (VSL) position. The VSL is detected as the plasma potential peak measured by a reciprocating ball-pen probe. A subsequent statistical analysis of nearly 400 discharges shows a strong systematic trend in the reconstructed separatrix position relative to the VSL, where the primary factors are plasma triangularity and the magnetic axis radial position. This dependency is significantly reduced after the measuring coils positions as recorded in EFIT input are optimised to provide a closer match between the „synthetic“ coil signal calculated by the Biot-Savart law in a vacuum discharge and the actual coil signal. In conclusion, we suggest that applying this optimisation may lead to more accurate and reliable reconstructions of the COMPASS equilibrium, which would have a positive impact on the accuracy of measurement analysis performed in the edge plasma.
    PracovištěÚstav fyziky plazmatu
    KontaktVladimíra Kebza, kebza@ipp.cas.cz, Tel.: 266 052 975
    Rok sběru2021
    Elektronická adresahttps://iopscience.iop.org/article/10.1088/1748-0221/14/11/C11020
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.