Počet záznamů: 1
Systematic errors in tokamak magnetic equilibrium reconstruction: A study of EFIT++ at tokamak COMPASS
- 1.
SYSNO ASEP 0531252 Druh ASEP J - Článek v odborném periodiku Zařazení RIV J - Článek v odborném periodiku Poddruh J Článek ve WOS Název Systematic errors in tokamak magnetic equilibrium reconstruction: A study of EFIT++ at tokamak COMPASS Tvůrce(i) Jiráková, Kateřina (UFP-V)
Kovanda, O. (CZ)
Adámek, Jiří (UFP-V) RID, ORCID
Komm, Michael (UFP-V) RID, ORCID
Seidl, Jakub (UFP-V) RIDCelkový počet autorů 5 Číslo článku C11020 Zdroj.dok. Journal of Instrumentation. - : Institute of Physics Publishing - ISSN 1748-0221
Roč. 14, č. 11 (2019)Poč.str. 7 s. Jazyk dok. eng - angličtina Země vyd. GB - Velká Británie Klíč. slova Analysis and statistical methods ; Plasma diagnostics ; probes Vědní obor RIV BL - Fyzika plazmatu a výboje v plynech Obor OECD Fluids and plasma physics (including surface physics) CEP GA19-15229S GA ČR - Grantová agentura ČR 8D15001 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy LM2015045 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy Způsob publikování Omezený přístup Institucionální podpora UFP-V - RVO:61389021 UT WOS 000507588300020 EID SCOPUS 85082806934 DOI 10.1088/1748-0221/14/11/C11020 Anotace Uncertainties and errors in magnetic equilibrium reconstructions are a wide-spread problem in interpreting experimental data measured in the tokamak edge. This study demonstrates errors in EFIT++ reconstructions performed on the COMPASS tokamak by comparing the outer midplane separatrix position to the Velocity Shear Layer (VSL) position. The VSL is detected as the plasma potential peak measured by a reciprocating ball-pen probe. A subsequent statistical analysis of nearly 400 discharges shows a strong systematic trend in the reconstructed separatrix position relative to the VSL, where the primary factors are plasma triangularity and the magnetic axis radial position. This dependency is significantly reduced after the measuring coils positions as recorded in EFIT input are optimised to provide a closer match between the „synthetic“ coil signal calculated by the Biot-Savart law in a vacuum discharge and the actual coil signal. In conclusion, we suggest that applying this optimisation may lead to more accurate and reliable reconstructions of the COMPASS equilibrium, which would have a positive impact on the accuracy of measurement analysis performed in the edge plasma. Pracoviště Ústav fyziky plazmatu Kontakt Vladimíra Kebza, kebza@ipp.cas.cz, Tel.: 266 052 975 Rok sběru 2021 Elektronická adresa https://iopscience.iop.org/article/10.1088/1748-0221/14/11/C11020
Počet záznamů: 1