Počet záznamů: 1  

Microwave reflectometer for density profile and turbulence measurements on the COMPASS tokamak

  1. 1.
    SYSNO ASEP0531029
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevMicrowave reflectometer for density profile and turbulence measurements on the COMPASS tokamak
    Tvůrce(i) Bogár, Ondrej (UFP-V) ORCID
    Zajac, Jaromír (UFP-V) RID
    Žáček, František (UFP-V) RID
    Varavin, Mykyta (UFP-V)
    Hron, Martin (UFP-V) RID, ORCID
    Pánek, Radomír (UFP-V) RID
    Silva, A. (PT)
    Celkový počet autorů7
    Číslo článku013515
    Zdroj.dok.Review of Scientific Instruments. - : AIP Publishing - ISSN 0034-6748
    Roč. 91, č. 1 (2020)
    Poč.str.8 s.
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovaCOMPASS ; tokamak ; turbulence measurement
    Vědní obor RIVBL - Fyzika plazmatu a výboje v plynech
    Obor OECDFluids and plasma physics (including surface physics)
    CEPLM2015045 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    GA19-15229S GA ČR - Grantová agentura ČR
    Způsob publikováníOmezený přístup
    Institucionální podporaUFP-V - RVO:61389021
    UT WOS000518011500003
    EID SCOPUS85078679114
    DOI10.1063/1.5099345
    AnotaceThe fast microwave reflectometer system on the COMPASS tokamak consists of an O-mode polarized K-band (18 GHz-26 GHz), Ka-band (26 GHz-40 GHz), and a part of U-band (40 GHz-54 GHz). The plasma density profile from the edge plasma area is measured using a fast sweeping rate up of to 6 μs of the probing wave. The processing of the reflected signal is realized by the heterodyne detection configuration based on the I/Q modulator. Two different methods of dynamic calibration of the required linear sweep frequency, together with static frequency and dispersion calibration, were used. The electron density profile was reconstructed by a spectrogram-based method with four sweeps on average. The system has the capability to measure the mid-plane low-field side electron density profile in the density range from 4 × 1018 m-3 to 3.6 × 1019 m-3. Experimental results obtained on COMPASS discharges are presented to demonstrate the performance of the diagnostics.
    PracovištěÚstav fyziky plazmatu
    KontaktVladimíra Kebza, kebza@ipp.cas.cz, Tel.: 266 052 975
    Rok sběru2021
    Elektronická adresahttps://aip.scitation.org/doi/10.1063/1.5099345
Počet záznamů: 1  