Linearity studies of HD-810 dosimeters by light ion beams

  1. 1.
    SYSNO ASEP0523919
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevLinearity studies of HD-810 dosimeters by light ion beams
    Tvůrce(i) Torrisi, Alfio (UJF-V) RID, ORCID
    Havránek, Vladimír (UJF-V) RID, SAI, ORCID
    Cutroneo, Mariapompea (UJF-V) ORCID, RID, SAI
    Vacík, Jiří (UJF-V) RID, ORCID, SAI
    Torrisi, L. (IT)
    Celkový počet autorů5
    Zdroj.dok.Radiation Effects and Defects in Solids. - : Taylor & Francis - ISSN 1042-0150
    Roč. 175, 3-4 (2020), s. 383-393
    Poč.str.11 s.
    Forma vydáníTištěná - P
    Jazyk dok.eng - angličtina
    Země vyd.GB - Velká Británie
    Klíč. slovadosimetry ; HD-810GafChromatic (TM) film ; ion beam ; ion dose ; optical spectroscopy ; radiation ; radiochromic film
    Vědní obor RIVBG - Jaderná, atomová a mol. fyzika, urychlovače
    Obor OECDNuclear physics
    CEPLM2015056 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    GA19-02482S GA ČR - Grantová agentura ČR
    EF16_013/0001812 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Způsob publikováníOmezený přístup
    Institucionální podporaUJF-V - RVO:61389005
    UT WOS000522130000015
    EID SCOPUS85082686791
    DOI10.1080/10420150.2019.1701469
    AnotaceRadiochromic films (RCF), also called GafChromic (TM) films, represent a performant material for accurate quantitative radiation dosimetry. Their compositions allow high dose sensitivity and fewer environmental dependence, giving a good feedback to the absorbed dose value and to the active media absorption, turning color upon being irradiated. The RCF take into account their reduced response near the Bragg peak due to a high linear energy transfer (LET). HD-810 GafChromic (TM) films are tissue-equivalent, have easy optical readings and can be employed for ion dosimetry in radio diagnostic and therapy and for industrial applications. Such dosimeters were employed at Tandetron-Nuclear Physics Institute (Rez, Czech Republic) to study the responses of helium, proton and carbon beams, commonly employed in radiotherapy and microelectronics. The sensitivity of the detector is low enough to measure multiple-beam exposures. The induced effects by the ions in the energy range of 600 keV to 2.0 MeV were investigated in terms of optical absorbance, measured in the irradiated active region of the polymer. The employed ion dose range was between 40 Gy and 2.5 kGy. The experimental results show that the absorbance increases with the irradiation time (i.e. with the absorbed dose). The absorbance induced in the radio chromic film was measured at 673 nm, at which is observed the highest sensitivity of the films. Such data, together with the dose linearity and the dependence on the ion stopping power will be presented and discussed.
    PracovištěÚstav jaderné fyziky
    KontaktMarkéta Sommerová, sommerova@ujf.cas.cz, Tel.: 266 173 228
    Rok sběru2021
    Elektronická adresahttps://doi.org/10.1080/10420150.2019.1701469