Gas−liquid contactors’ aeration capacities when agitated by Rushton turbines of various diameters

  1. 1.
    SYSNO ASEP0523478
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevGas−liquid contactors’ aeration capacities when agitated by Rushton turbines of various diameters
    Tvůrce(i) Kracík, T. (CZ)
    Moucha, T. (CZ)
    Petříček, Radim (UH-J) RID, ORCID, SAI
    Zdroj.dok.ACS Omega. - : American Chemical Society - ISSN 2470-1343
    Roč. 5, č. 10 (2020), s. 5072-5077
    Poč.str.6 s.
    Forma vydáníOnline - E
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovamass transfer ; bubbles ; theoretical and computational chemistry ; Rushton turbine
    Vědní obor RIVBK - Mechanika tekutin
    Obor OECDFluids and plasma physics (including surface physics)
    Způsob publikováníOpen access
    Institucionální podporaUH-J - RVO:67985874
    UT WOS000520853400039
    EID SCOPUS85081694628
    DOI10.1021/acsomega.9b04005
    AnotaceMass transfer processes are one of the most important operations in chemical, biochemical, and food industries worldwide. In the processes that are controlled by the gas-liquid mass transfer rate, the volumetric mass transfer coefficient kLa becomes a crucial quantity. The dataset was measured with the aim to create a correlation for kLa prediction in a non-coalescent batch under the wide range of experimental conditions. The dynamic pressure method, which was reported as physically correct in the past, was chosen to be the method for experimental determination of kLa. Our previous work targeted the kLa dependencies in viscous and coalescent batches resulting in correlations that are viable for the broad range of process conditions. We reported that the best-fit correlation is based on the hydrodynamic parameter circumferential velocity of impeller blades in the case of non-coalescent liquids in the vessel equipped by single or multiple impellers at a constant D/T ratio (diameter of the impeller to the inner diameter of the tank). Now, we focus on the influence of various impeller diameters on transport characteristics (mainly kLa) in a non-coalescent batch. The experiments are carried out in a multiple-impeller vessel equipped with Rushton turbines (of four diameters) and in both laboratory and pilot-plant scales. Various impeller frequencies and gas flow rates are used. We examine the suitability of the hydrodynamic description, which was reported in the past, to predict kLa also when the D/T ratio changes. We show that the correlation based on the energy dissipation rate better fits the experimental data and predicts kLa values more accurately in the case of varying D/T values. This correlation could be adopted in the design and scale-up of agitated devices operating with non-coalescent batches.
    PracovištěÚstav pro hydrodynamiku
    KontaktSoňa Hnilicová, hnilicova@ih.cas.cz, Tel.: 233 109 003
    Rok sběru2021
    Elektronická adresahttp://hdl.handle.net/11104/0307838