Počet záznamů: 1
Measurement of the photon identification efficiencies with the ATLAS detector using LHC Run-1 data
- 1.
SYSNO ASEP 0522562 Druh ASEP J - Článek v odborném periodiku Zařazení RIV J - Článek v odborném periodiku Poddruh J Článek ve WOS Název Measurement of the photon identification efficiencies with the ATLAS detector using LHC Run-1 data Tvůrce(i) Aaboud, M. (MA)
Aad, G. (FR)
Abbott, B. (US)
Chudoba, Jiří (FZU-D) RID, ORCID
Havránek, Miroslav (FZU-D) RID
Hejbal, Jiří (FZU-D) RID, ORCID
Jakoubek, Tomáš (FZU-D) RID, ORCID
Kepka, Oldřich (FZU-D) RID, ORCID
Kupčo, Alexander (FZU-D) RID, ORCID
Kůs, Vlastimil (FZU-D) RID
Lokajíček, Miloš (FZU-D) RID, ORCID
Lysák, Roman (FZU-D) RID, ORCID
Marčišovský, Michal (FZU-D) RID, ORCID
Mikeštíková, Marcela (FZU-D) RID, ORCID
Němeček, Stanislav (FZU-D) RID, ORCID
Penc, Ondřej (FZU-D) ORCID
Šícho, Petr (FZU-D) RID, ORCID
Staroba, Pavel (FZU-D) RID, ORCID
Svatoš, Michal (FZU-D) RID, ORCID
Taševský, Marek (FZU-D) RID, ORCID
Vrba, Václav (FZU-D) RID, ORCIDCelkový počet autorů 2856 Číslo článku 666 Zdroj.dok. European Physical Journal C. - : Springer - ISSN 1434-6044
Roč. 76, č. 12 (2016), s. 1-42Poč.str. 42 s. Jazyk dok. eng - angličtina Země vyd. US - Spojené státy americké Klíč. slova ATLAS ; CERN LHC Coll ; photon: rapidity ; numerical calculations: Monte Carlo ; 7000 GeV-cms ; experimental results ; 8000 GeV-cms Vědní obor RIV BF - Elementární částice a fyzika vys. energií Obor OECD Particles and field physics Způsob publikování Open access Institucionální podpora FZU-D - RVO:68378271 UT WOS 000389890600001 EID SCOPUS 85003480972 DOI 10.1140/epjc/s10052-016-4507-9 Anotace The algorithms used by the ATLAS Collaboration to reconstruct and identify prompt photons are described. Measurements of the photon identification efficiencies are reported, using 4.9 fb−1 of pp collision data collected at the LHC at √s=7 TeV and 20.3 fb−1 at √s=8 TeV . The efficiencies are measured separately for converted and unconverted photons, in four different pseudorapidity regions, for transverse momenta between 10 GeV and 1.5 TeV . The results from the combination of three data-driven techniques are compared to the predictions from a simulation of the detector response, after correcting the electromagnetic shower momenta in the simulation for the average differences observed with respect to data. Data-to-simulation efficiency ratios used as correction factors in physics measurements are determined to account for the small residual efficiency differences. Pracoviště Fyzikální ústav Kontakt Kristina Potocká, potocka@fzu.cz, Tel.: 220 318 579 Rok sběru 2020 Elektronická adresa http://hdl.handle.net/11104/0307033
Počet záznamů: 1