Vapour-liquid equilibria in water plus poly(ethylene glycol) systems: New experiments and cumulative thermodynamic processing of all data.

  1. 1.
    SYSNO ASEP0522193
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevVapour-liquid equilibria in water plus poly(ethylene glycol) systems: New experiments and cumulative thermodynamic processing of all data.
    Tvůrce(i) Pavlíček, Jan (UCHP-M) RID, SAI
    Bogdanić, Grozdana (UCHP-M) RID, ORCID, SAI
    Wichterle, Ivan (UCHP-M) RID, ORCID, SAI
    Izák, Pavel (UCHP-M) RID, ORCID, SAI
    Číslo článku105901
    Zdroj.dok.Journal of Chemical Thermodynamics. - : Elsevier - ISSN 0021-9614
    Roč. 140, JAN 2020 (2020)
    Poč.str.9 s.
    Jazyk dok.eng - angličtina
    Země vyd.GB - Velká Británie
    Klíč. slovaexperimental data ; poly(ethylene glycol) ; vapour-liquid equilibrium ; correlation
    Vědní obor RIVCF - Fyzikální chemie a teoretická chemie
    Obor OECDPhysical chemistry
    CEPGA18-05484S GA ČR - Grantová agentura ČR
    Způsob publikováníOpen access
    Institucionální podporaUCHP-M - RVO:67985858
    UT WOS000485102200018
    EID SCOPUS85070918293
    DOI10.1016/j.jct.2019.105901
    AnotaceDependences of total pressure on the composition of water + poly(ethylene glycol) systems were measured with both the ebulliometric and static method. New data on vapour-liquid equilibria cover the temperature range 303.15–363.15 K and the range of the weight fraction of solvent 0.5–1.0 for polymers of nominal molecular weight 1000, 3000, and 6000 g mol-1. These data together with those determined earlier were correlated using the UNIQUAC free-volume (FV) model to be consistent with previous studies. In addition, all available literature data on this system were processed in the same way. As a result, the obtained average deviations were used as indicators of data quality. Average deviation of experimental
    and calculated solvent activity was about 0.0004 for all our data. The evaluated adjustable parameters were proportional to molecular weight, which ensures reliable interpolation and even extrapolation beyond the investigated temperature and molecular weight ranges.
    PracovištěÚstav chemických procesů
    KontaktEva Jirsová, jirsova@icpf.cas.cz, Tel.: 220 390 227
    Rok sběru2021
    Elektronická adresahttps://www.sciencedirect.com/science/article/pii/S0021961419301405?via%3Dihub