Počet záznamů: 1  

Label-free electrochemical analysis of purine nucleotides and nucleobases at disposable carbon electrodes in microliter volumes

  1. 1.
    SYSNO ASEP0518362
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevLabel-free electrochemical analysis of purine nucleotides and nucleobases at disposable carbon electrodes in microliter volumes
    Tvůrce(i) Hasoň, Stanislav (BFU-R) RID, ORCID
    Fojta, Miroslav (BFU-R) RID, ORCID
    Ostatná, Veronika (BFU-R) RID, ORCID
    Celkový počet autorů3
    Číslo článku113252
    Zdroj.dok.Journal of Electroanalytical Chemistry. - : Elsevier - ISSN 1572-6657
    Roč. 847, AUG 15 2019 (2019)
    Poč.str.7 s.
    Forma vydáníOnline - E
    Jazyk dok.eng - angličtina
    Země vyd.CH - Švýcarsko
    Klíč. slovadna bases ; pencil electrodes ; graphene ; graphite
    Vědní obor RIVCG - Elektrochemie
    Obor OECDAnalytical chemistry
    CEPGA17-08971S GA ČR - Grantová agentura ČR
    EF15_003/0000477 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Způsob publikováníOmezený přístup
    Institucionální podporaBFU-R - RVO:68081707
    UT WOS000482532200065
    DOI10.1016/j.jelechem.2019.113252
    AnotaceWe analyzed purine nucleotides in oligodeoxynucleotides (ODN) and nucleobase residues acid-hydrolyzed ODN at nanomolar concentrations in few tens of microliters of solution at commercially available unmodified graphite pencil electrodes, screen printed graphite electrodes (SPGEs) and SPGEs modified by graphene, single- and multi-walled carbon nanotubes. Our results suggest that specific properties of different graphite-based electrodes have significant impact on ODN analysis. Nanostructure-modified electrodes produced higher signals due to purine nucleobase oxidation but also higher background currents. The unmodified disposable carbon electrodes allowed analysis of both free nucleobases and ODNs. Our results show that unmodified SPGEs represent a good compromise for signal/noise ratio. Electrooxidation of purines at these electrodes was only little affected by the presence of pyrimidines in contrast to the pencil graphite electrode.
    PracovištěBiofyzikální ústav
    KontaktJana Poláková, polakova@ibp.cz, Tel.: 541 517 244
    Rok sběru2020
    Elektronická adresahttps://www.sciencedirect.com/science/article/pii/S157266571930520X?via%3Dihub
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.