Počet záznamů: 1  

Structured and graphitized boron doped diamond electrodes: Impact on electrochemical detection of Cd.sup.2+./sup. and Pb.sup.2+./sup. ions

  1. 1.
    SYSNO ASEP0517535
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevStructured and graphitized boron doped diamond electrodes: Impact on electrochemical detection of Cd2+ and Pb2+ ions
    Tvůrce(i) Štenclová, Pavla (FZU-D) ORCID
    Vyskočil, V. (CZ)
    Szabó, Ondrej (FZU-D) ORCID, RID
    Ižák, Tibor (FZU-D) RID
    Potocký, Štěpán (FZU-D) RID, ORCID
    Kromka, Alexander (FZU-D) RID, ORCID, SAI
    Celkový počet autorů6
    Číslo článku108953
    Zdroj.dok.Vacuum. - : Elsevier - ISSN 0042-207X
    Roč. 170, Dec (2019), s. 1-7
    Poč.str.7 s.
    Jazyk dok.eng - angličtina
    Země vyd.GB - Velká Británie
    Klíč. slovaboron doped diamond ; reactive ion etching ; structuring ; nanorods ; cyclic voltammetry
    Vědní obor RIVCG - Elektrochemie
    Obor OECDElectrochemistry (dry cells, batteries, fuel cells, corrosion metals, electrolysis)
    CEPEF16_019/0000760 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    GA17-19968S GA ČR - Grantová agentura ČR
    Způsob publikováníOmezený přístup
    Institucionální podporaFZU-D - RVO:68378271
    UT WOS000498325300001
    EID SCOPUS85072538979
    DOI10.1016/j.vacuum.2019.108953
    AnotaceHere we introduce the structuring of boron doped diamond (BDD) electrodes using a self-organised mask and reactive ion etching (RIE) in oxygen plasma for electrochemical measurements of selected metal ions. The samples were analysed by SEM, Raman and X-ray photoelectron spectroscopy. The electrochemical performance of structured BDD was compared to as-grown BDD and standard glassy carbon (GC) electrodes employing standard cyclic voltammetry and differential pulse anodic stripping voltammetry. Separate and simultaneous detection of Cd2+- and Pb2+ ions is discussed in relation to the electrode morphology and content of graphitic phase. To determine trace amounts of metal ions we evaluated the repeatability of measurements, which is statistically expressed as the relative standard deviation (RSD) of consecutive determinations.
    PracovištěFyzikální ústav
    KontaktKristina Potocká, potocka@fzu.cz, Tel.: 220 318 579
    Rok sběru2020
    Elektronická adresahttps://doi.org/10.1016/j.vacuum.2019.108953
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.