Simulation of optimal measurement setting and calibration of a novel time-offlight spectrometer

  1. 1.
    SYSNO ASEP0510317
    Druh ASEPA - Abstrakt
    Zařazení RIVZáznam nebyl označen do RIV
    Zařazení RIVNení vybrán druh dokumentu
    NázevSimulation of optimal measurement setting and calibration of a novel time-offlight spectrometer
    Tvůrce(i) Zouhar, Martin (UPT-D) ORCID, RID, SAI
    Daniel, Benjamin (UPT-D) RID
    Radlička, Tomáš (UPT-D) RID, ORCID, SAI
    Oral, Martin (UPT-D) RID, ORCID, SAI
    Konvalina, Ivo (UPT-D) RID, ORCID, SAI
    Celkový počet autorů5
    Zdroj.dok.Microscopy Conference: MC 2019. Abstracts. - Berlin : DSE, 2019
    S. 603-604
    Poč.str.2 s.
    Forma vydáníOnline - E
    AkceMicroscopy Conference : MC 2019
    Datum konání01.09.2019 - 05.09.2019
    Místo konáníBerlin
    ZeměDE - Německo
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.DE - Německo
    Klíč. slovameasurement setting and calibration ; novel time-offlight
    Vědní obor RIVJA - Elektronika a optoelektronika, elektrotechnika
    Obor OECDElectrical and electronic engineering
    CEPTN01000008 GA TA ČR - Technologická agentura ČR
    TE01020118 GA TA ČR - Technologická agentura ČR
    Institucionální podporaUPT-D - RVO:68081731
    AnotaceWe present setting optimal measurement parameters of components of the time-of-flight (ToF) spectrometer via electron tracing in the regions below the sample. The results of the optimization are used to generate a time-to-energy (T2E) conversion table and to consequently convert spectra measured in the time-domain.
    The goal is to find optimal potentials on the electrodes of the ToF spectrometer which shall be used during
    measurement and in creation of the T2E conversion table.
    A particle tracing library is used to generate data for a given set of values of voltages at the components of the ToF spectrometer for specified outgoing energies up to the landing energy (LE) and angles. The relevant part of the data consists of the triplet the ToF, the angle, and the energy. These values are used to construct a descriptor Q that is optimized to reach the best achievable properties of the spectrometer. Q consists of three interrelated contributions. The first is the signal S, ratio of the counts of the detected and emitted electrons. The second is the resolution R, constructed from a time-spread due to multiple electron trajectories with the same outgoing energy but different angles being detected. The third is the length of the spectrum in the time-domain T, the difference in the ToF corresponding to the LE and some (lower) reference energy. The quantity Q is optimized and the data set of the triplets (ToF, angle, energy) corresponding to the optimal point in the voltage space are used to generate the T2E conversion table.
    PracovištěÚstav přístrojové techniky