Počet záznamů: 1  

A modular trap-and-atomizer device with gold absorber for selenium collection after hydride generation

  1. 1.
    SYSNO ASEP0505805
    Druh ASEPA - Abstrakt
    Zařazení RIVZáznam nebyl označen do RIV
    Zařazení RIVNení vybrán druh dokumentu
    NázevA modular trap-and-atomizer device with gold absorber for selenium collection after hydride generation
    Tvůrce(i) Machado, I. (UY) ORCID
    Pistón, M. (UY)
    Musil, Stanislav (UIACH-O) RID, ORCID
    Dědina, Jiří (UIACH-O) RID, ORCID
    Kratzer, Jan (UIACH-O) RID, ORCID
    Celkový počet autorů5
    Zdroj.dok.Colloquium Spectroscopicum Internationale XLI & I Latin American Meeting on LIBS. Book of Abstracts. -, 2019
    O.At.3
    Poč.str.1 s.
    Forma vydáníNosič - C
    AkceColloquium Spectroscopicum Internationale /XLI./ & Latin American Meeting on LIBS /I./ CSI XLI
    Datum konání09.06.2019 - 14.06.2019
    Místo konáníMexico City
    ZeměMX - Mexiko
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.MX - Mexiko
    Klíč. slovaselenium trapping ; gold absorber ; hydride generation
    Vědní obor RIVCB - Analytická chemie, separace
    Obor OECDAnalytical chemistry
    CEPGA18-01116S GA ČR - Grantová agentura ČR
    Institucionální podporaUIACH-O - RVO:68081715
    AnotaceIn this work, a novel design of a device to trap hydrides and to volatilize the analyte to be detected by AAS was employed. This device consists of a modular trap-and-atomizer which allows a simple replacement of the inlet arm that serves as the trap. The device with a gold absorber was employed for Se collection. The relevant experimental
    conditions (hydrogen flow rate, trapping temperature and volatilization temperature) were optimized by using 75Se radiotracer and AAS experiments. Several arrangements of the gold absorber were tested to maximize the signal/noise ratio. A limit of detection of 7 pg mL-1 was found for the optimum arrangement. Results of analysis of water standard
    reference materials (TMRAIN-04 and SRM 1643e) provided good trueness and precision. The substantial advantage of this modular design is that it makes feasible to work with various modifications of the trap surface and with different absorbers placed inside the trap. The design appears to be promising for collection of other hydrides forming elements
    such as As.