Počet záznamů: 1  

Simple Approaches to on-Line and off-Line Speciation Analysis of Mercury in Flue Gases with Detection by Atomic Absorption Spectrometry: A Pilot Study.

  1. 1.
    SYSNO ASEP0504870
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevSimple Approaches to on-Line and off-Line Speciation Analysis of Mercury in Flue Gases with Detection by Atomic Absorption Spectrometry: A Pilot Study.
    Tvůrce(i) Švehla, Jaroslav (UCHP-M)
    Žídek, R. (CZ)
    Ružovič, Tomáš (UCHP-M) RID, ORCID, SAI
    Svoboda, Karel (UCHP-M) RID, ORCID, SAI
    Kratzer, J. (CZ)
    Zdroj.dok.Spectrochimica Acta Part B: Atomic Spectroscopy. - : Elsevier - ISSN 0584-8547
    Roč. 156, JUN (2019), s. 51-58
    Poč.str.8 s.
    Jazyk dok.eng - angličtina
    Země vyd.NL - Nizozemsko
    Klíč. slovamercury ; speciation analysis ; flue gases
    Vědní obor RIVDI - Znečištění a kontrola vzduchu
    Obor OECDEnvironmental sciences (social aspects to be 5.7)
    CEPEF16_026/0008413 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Způsob publikováníOmezený přístup
    Institucionální podporaUCHP-M - RVO:67985858
    UT WOS000471667900007
    EID SCOPUS85065308903
    DOI10.1016/j.sab.2019.05.002
    AnotaceTwo simple approaches to speciation analysis of mercury in flue gases have been developed distinguishing between elemental mercury Hg 0 and oxidized form of mercury (often HgCl 2 )either in off-line or on-line measurement arrangements. Both approaches employ atomic absorption spectrometry (AAS)as a detector. The off-line approach combines a pair of sorbents from which the first one traps oxidized for of mercury (HgCl 2 )selectively on a raw alumina sorbent while the second one retains Hg 0 quantitatively on a gold-coated alumina filling. Trapped amount of Hg in both sorbents is subsequently determined by AAS employing the advanced mercury analyzer AMA-254. Both sorbents can be regenerated for repeated use. Selectivity and capacity of both sorbents was investigated by means of model gases and compared to other materials. The accuracy and precision of this approach have been proven by analysis of a model flue gas mixture. The on-line approach to speciation analysis is based on direct introduction of flue gases into the AAS spectrometer equipped with an externally heated quartz tube atomizer. The temperature of the atomizer's optical arm or temperature of the gas line upstream the atomizer allow speciation analysis since Hg 0 as atomic Hg-vapor can be detected at ambient temperature while HgCl 2 as a molecular species requires heating of the atomizer or gas line to 900 °C.
    PracovištěÚstav chemických procesů
    KontaktEva Jirsová, jirsova@icpf.cas.cz, Tel.: 220 390 227
    Rok sběru2020
    Elektronická adresahttp://hdl.handle.net/11104/0296414