Počet záznamů: 1
Nanocrystalline diamond-based impedance sensors for real-time monitoring of adipose tissue-derived stem cells
- 1.
SYSNO ASEP 0504656 Druh ASEP J - Článek v odborném periodiku Zařazení RIV J - Článek v odborném periodiku Poddruh J Článek ve WOS Název Nanocrystalline diamond-based impedance sensors for real-time monitoring of adipose tissue-derived stem cells Tvůrce(i) Procházka, Václav (FZU-D) ORCID
Matějka, Roman (FGU-C) RID, ORCID, SAI
Ižák, Tibor (FZU-D) RID
Szabó, Ondrej (FZU-D) ORCID, RID
Štěpanovská, Jana (FZU-D)
Filová, Elena (FGU-C) RID, ORCID
Bačáková, Lucie (FGU-C) RID, ORCID
Jirásek, Vít (FZU-D) RID
Kromka, Alexander (FZU-D) RID, ORCID, SAICelkový počet autorů 9 Zdroj.dok. Colloids and Surfaces B-Biointerfaces. - : Elsevier - ISSN 0927-7765
Roč. 177, May (2019), s. 130-136Poč.str. 7 s. Jazyk dok. eng - angličtina Země vyd. NL - Nizozemsko Klíč. slova diamond film ; biosensor ; stem cells ; impedance spectroscopy Vědní obor RIV JB - Senzory, čidla, měření a regulace Obor OECD Electrical and electronic engineering Vědní obor RIV – spolupráce Fyziologický ústav - Biotechnologie a bionika CEP NV15-33018A GA MZd - Ministerstvo zdravotnictví EF16_019/0000760 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy Způsob publikování Omezený přístup Institucionální podpora FZU-D - RVO:68378271 ; FGU-C - RVO:67985823 UT WOS 000468720700015 EID SCOPUS 85060851825 DOI 10.1016/j.colsurfb.2019.01.048 Anotace Here we present a diamond-based impedance sensor with built-in gold IDT as a promising platform for simultaneous electrical and optical monitoring of adipose tissue-derived stem cells (ASCs). The impedance spectra were collected in a wide frequency from 100 Hz to 50 kHz for 90 h of cell cultivation. Absolute impedance spectra were analyzed in terms of cell properties monitored by a high-resolution digital camera. The sensors detected three phases of cell growth: the phase of cell attachment and spreading, the phase of cell proliferation, and the stationary phase without significant changes in cell number. These results were confirmed by simultaneous live cell imaging. The design of the sensing electrode is discussed, pointing out its enhanced sensitivity for a certain case. The diamond-based sensor appeared to be more sensitive for detecting the cell-substrate interaction in the first phase of cell growth, while the control system was more sensitive in the second phase of cell growth. Pracoviště Fyzikální ústav Kontakt Kristina Potocká, potocka@fzu.cz, Tel.: 220 318 579 Rok sběru 2020 Elektronická adresa https://doi.org/10.1016/j.colsurfb.2019.01.048
Počet záznamů: 1