Počet záznamů: 1  

Capillary electrophoresis with preparative isoelectric focusing preconcentration for sensitive determination of amphotericin B in human blood serum

  1. 1.
    SYSNO ASEP0501010
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevCapillary electrophoresis with preparative isoelectric focusing preconcentration for sensitive determination of amphotericin B in human blood serum
    Tvůrce(i) Šalplachta, Jiří (UIACH-O) RID, ORCID
    Horká, Marie (UIACH-O) RID, ORCID
    Šlais, Karel (UIACH-O) RID, ORCID
    Celkový počet autorů3
    Zdroj.dok.Analytica Chimica Acta. - : Elsevier - ISSN 0003-2670
    Roč. 1053, APR (2019), s. 162-168
    Poč.str.7 s.
    Forma vydáníTištěná - P
    Jazyk dok.eng - angličtina
    Země vyd.NL - Nizozemsko
    Klíč. slovacapillary zone electrophoresis ; Amphotericin B ; blood ; sample preparation
    Vědní obor RIVCB - Analytická chemie, separace
    Obor OECDAnalytical chemistry
    CEPGA16-03749S GA ČR - Grantová agentura ČR
    NV16-29916A GA MZd - Ministerstvo zdravotnictví
    VI20172020069 GA MV - Ministerstvo vnitra
    Způsob publikováníOmezený přístup
    Institucionální podporaUIACH-O - RVO:68081715
    UT WOS000457201600018
    EID SCOPUS85058795138
    DOI10.1016/j.aca.2018.12.010
    AnotaceAmphotericin B (AmB) is still, despite its severe nephrotoxicity, the first-line agent in the management of serious systemic fungal infections. A sensitive and reliable method is therefore required to control AmB concentration in body fluids of a patient. This study demonstrates the potential of the off-line combination of preparative isoelectric focusing (IEF) with capillary isoelectric focusing (CIEF) or capillary zone electrophoresis (CZE) in the determination of AmB in human blood serum. The required value of the isoelectric point of AmB was determined to be 6.1 using the CIEF technique. Preparative IEF served as a pre-separation and concentration technique. The pH gradient was traced by colored low molecular pI markers. The collected fraction with AmB was easily processed and then analyzed by CIEF and CZE. Tens of picograms of AmB in human blood serum sample can be determined by a combination of preparative IEF with CZE. The method was linear in the AmB concentration range of 0.3e600 ngmL 1. The recovery ranged from 93% to 98%.
    PracovištěÚstav analytické chemie
    KontaktIveta Drobníková, drobnikova@iach.cz, Tel.: 532 290 234
    Rok sběru2020
    Elektronická adresahttp://hdl.handle.net/11104/0293037