Measurement system for characterization of angular and spectral distribution of LED based sources

  1. 1.
    SYSNO ASEP0498732
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevMeasurement system for characterization of angular and spectral distribution of LED based sources
    Tvůrce(i) Šerý, Mojmír (UPT-D) RID, SAI
    Ježek, Jan (UPT-D) RID, ORCID, SAI
    Jákl, Petr (UPT-D) RID, ORCID, SAI
    Škereň, M. (CZ)
    Zemánek, Pavel (UPT-D) RID, SAI, ORCID
    Celkový počet autorů5
    Číslo článku1097607
    Zdroj.dok.21st Czech-Polish-Slovak Optical Conference on Wave and Quantum Aspects of Contemporary Optics. (Proceedings of SPIE 10976). - Bellingham : SPIE, 2018 / Zemánek Pavel - ISSN 0277-786X - ISBN 9781510626072
    Poč.str.4 s.
    Forma vydáníTištěná - P
    AkceCzech-Polish-Slovak Optical Conference on Wave and Quantum Aspects of Contemporary Optics /21./
    Datum konání03.09.2018 - 07.09.2018
    Místo konáníLednice
    ZeměCZ - Česká republika
    Typ akceEUR
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovalight emitting diodes ; light distribution
    Vědní obor RIVBH - Optika, masery a lasery
    Obor OECDOptics (including laser optics and quantum optics)
    CEPFV10618 GA MPO - Ministerstvo průmyslu a obchodu
    TE01020233 GA TA ČR - Technologická agentura ČR
    LO1212 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    ED0017/01/01 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaUPT-D - RVO:68081731
    UT WOS000455324600006
    EID SCOPUS85059420981
    DOI10.1117/12.2518360
    AnotaceIn the present days light emitting diodes1 (LED) based light sources become very common in most areas of life2 and scientific applications3. Due to the nature characteristic of the LED’s, angular and spectral distribution of the emitted light must be improved for specific purposes of light source4. It could be done by standard bulk optics, reflective and refractive, or in modern way by integrating planar diffractive structures. Measuring system of spatial distribution of illumination was developed, which could be used in general but with advantage mainly for improved progressive diffraction optics components. The measurement system consists of three main parts. The first one is rigid optical bench with goniometric light source holder driven by stepper motor, which operates in three degrees of freedom. The source holder has ability to correct thickness of the light source with respect to the plane of the radiation. Maximal size of the light source is 500 by 500 mm and maximal length between the source and detector part is over 3 meters. The second detection part includes fiber spectrometer, photopic photodiode and elevation laser. Latter ensures correct repeatable