Počet záznamů: 1  

High-fidelity multimode fibre-based endoscopy for deep brain in vivo imaging

  1. 1.
    SYSNO ASEP0497594
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevHigh-fidelity multimode fibre-based endoscopy for deep brain in vivo imaging
    Tvůrce(i) Turtaev, S. (DE)
    Leite, I. T. (DE)
    Altwegg-Boussac, T. (GB)
    Pakan, J.M.P. (GB)
    Rochefort, N.L. (GB)
    Čižmár, Tomáš (UPT-D) RID, ORCID, SAI
    Celkový počet autorů6
    Číslo článku92
    Zdroj.dok.Light-Science & Applications. - : Springer - ISSN 2047-7538
    Roč. 7, č. 1 (2018)
    Poč.str.8 s.
    Forma vydáníTištěná - P
    Jazyk dok.eng - angličtina
    Země vyd.GB - Velká Británie
    Klíč. slovaoptical-fiber ; focusing light ; transmission ; amplitude
    Vědní obor RIVBH - Optika, masery a lasery
    Obor OECDOptics (including laser optics and quantum optics)
    CEPEF15_003/0000476 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaUPT-D - RVO:68081731
    UT WOS000450708600003
    EID SCOPUS85057042186
    DOI10.1038/s41377-018-0094-x
    AnotaceProgress in neuroscience relies on new techniques for investigating the complex dynamics of neuronal networks. An ongoing challenge is to achieve minimally invasive and high-resolution observations of neuronal activity in vivo inside deep brain areas. Recently introduced methods for holographic control of light propagation in complex media enable the use of a hair-thin multimode optical fibre as an ultranarrow imaging tool. Compared to endoscopes based on graded-index lenses or fibre bundles, this new approach offers a footprint reduction exceeding an order of magnitude, combined with a significant enhancement in resolution. We designed a compact and high-speed system for fluorescent imaging at the tip of a fibre, achieving a resolution of 1.18 +/- 0.04 mu m across a 50-mu m field of view, yielding 7-kilopixel images at a rate of 3.5 frames/s. Furthermore, we demonstrate in vivo observations of cell bodies and processes of inhibitory neurons within deep layers of the visual cortex and hippocampus of anaesthetised mice. This study paves the way for modern microscopy to be applied deep inside tissues of living animal models while exerting a minimal impact on their structural and functional properties.
    PracovištěÚstav přístrojové techniky
    KontaktMartina Šillerová, sillerova@ISIBrno.Cz, Tel.: 541 514 178
    Rok sběru2019
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.